Expert Power Control NET 4x 8212 / 8213 Content 3 Table of content Kapitel 1 Security Advise 5 Kapitel 2 Description 5 Kapitel 3 Hardware 6 3.1 Content of delivery 6 3.2 Connections 7 3.3 Installation 7 Kapitel 4 Configuration 8 4.1 DHCP 8 4.2 Network settings with GBL_Conf 8 4.3 Configuration via webinterface 9 4.3.1 Configuration - Power Ports 9 4.3.2 Configuration - IP address 12 4.3.3 Configuration - IP ACL 13 4.3.4 Configuration - HTTP 13 4.3.
Expert Power Control NET 4x 8212 / 8213 Content 4 Kapitel 7 Support 22 Kapitel 8 Declarations of conformity 23 © 2010 Gude Analog- und Digitalsysteme GmbH
Expert Power Control NET 4x 8212 / 8213 1 Security Advise 5 Security Advise The device must be installed only by qualified personnel according to the following installation and operating instructions. The manufacturer does not accept responsibility in case of improper use of the device and particularly any use of equipment that may cause personal injury or material damage. The device contains no user-maintenable parts. All maintenance has to be performed by factorytrained service personnel.
Expert Power Control NET 4x 8212 / 8213 3 3.
Expert Power Control NET 4x 8212 / 8213 3.2 Hardware 7 Connections Connections Expert Power Control NET 4x 8212 Connections Expert Power Control NET 4x 8213 1) Power Port LEDs 2) Buttons "select" and "ok" 3) Status LED 4) Aux connector for serial interface (RS232-PS2 cable) or Sensor 5) TEMP connector for Sensor 6) Ethernet connector (RJ45) 7) Display 8) 8 Power Ports (IEC C13, max. 10A) 9) Power supply (IEC C20, max. 16A) 3.3 Installation 1.
Expert Power Control NET 4x 8212 / 8213 4 4.1 Hardware 8 Configuration DHCP After switch-on Expert Power Control NET 8x 8210 / 8211 looks for a DHCP server and requests an available IP address . Please check the IP address allocated to Expert Power Control NET 8x 8210 / 8211 in the DHCP server settings to make sure that the same address is used at every reboot. 4.2 Network settings with GBL_Conf For changing the network properties manually, the program GBL_Conf.exe is required.
Expert Power Control NET 4x 8212 / 8213 4.3 Configuration 9 Configuration via webinterface Go to the website of Expert Power Control NET 8x 8210 / 8211. Enter the IP address of Expert Power Control NET 8x 8210 / 8211 into the address line of your internet browser: http://”IP address of Expert Power Control NET 8x 8210 / 8211”/ and press LOGIN. To enter the configuration menu, click on „Configuration“ on the upper left side of the screen. 4.3.
Expert Power Control NET 4x 8212 / 8213 4.3.1.1 Configuration 10 Label A name with a maximum of 15 characters can be entered here for each Power Port. 4.3.1.2 After power-up switch The Power Port’s switching state after a power-on of the device can be defined here (on, off, remember last state). 4.3.1.3 If switching on after power-up, wait ... A switching delay of a Power Port can be defined here that is applied after switch on of the device. The delay can last up to 8191 seconds. 4.3.1.
Expert Power Control NET 4x 8212 / 8213 Configuration When a watchdog reset a power port, the watchdog again waits for a first ping reply, as stated above. 4.3.1.5.1 Enable Watchdog Here you can activate the watchdog for this power port. 4.3.1.5.2 Watchdog type Here you can switch between ICMP ping or TCP ping. 4.3.1.5.3 Host IP Here you can enter the IP address this watchdog should observe. 4.3.1.5.4 TCP Port If TCP pings are used, here you can enter the TCP port.
Expert Power Control NET 4x 8212 / 8213 4.3.2 Configuration - IP address 4.3.2.1 Hostname Configuration 12 Enter the host name of Expert Power Control NET 8x 8210 / 8211. Expert Power Control NET 8x 8210 / 8211 uses this name to connect with DHCP server. Special signs may destabilize your network. All changes need a restart of the firmware to get valid. 4.3.2.2 IP Address Here you can change the IP address of Expert Power Control NET 8x 8210 / 8211.
Expert Power Control NET 4x 8212 / 8213 4.3.3 Configuration 13 Configuration - IP ACL IP Access Control List (IP ACL) acts as an IP filter for your Expert Power Control NET 8x 8210 / 8211. Wether it is active hosts and subnets only can contact Expert Power Control NET 8x 8210 / 8211, if their IP adresses are stated in this IP ACL. e.g.: „http://192.168.0.1“ or „http://192.168.0.
Expert Power Control NET 4x 8212 / 8213 4.3.4.1 Configuration 14 HTTP Port Here you can enter the HTTP port number, if necessary. Possible numbers are 1 ... 65534 (standard: 80). To get access to Expert Power Control NET 8x 8210 / 8211, you have to enter the port number behind the IP address of Expert Power Control NET 8x 8210 / 8211, e.g.: http://192.168.0.2:1720 All changes need a restart of the firmware to get valid. 4.3.4.2 Require HTTP Password Password protected access can be activated here.
Expert Power Control NET 4x 8212 / 8213 4.3.5.3 Configuration 15 Min. Temperature Here you can define the minimum temperature, if the sensor measures this temperature the device will generate an alert via SNMP and Syslog. 4.3.6 Configuration - SNMP 4.3.6.1 SNMP To get detailed status information of Expert Power Control NET 8x 8210 / 8211 SNMP can be used. SNMP communicates via UDP (port 161) with Expert Power Control NET 8x 8210 / 8211: You can use SNMP to switch the power ports as well.
Expert Power Control NET 4x 8212 / 8213 4.3.6.2 Configuration 16 Enable SNMP-get Here you can activate SNMP-get protocol of Expert Power Control NET 8x 8210 / 8211. Use SNMP only if your network is fitted for. 4.3.6.3 Community public Here you can enter the SNMP public community. Use SNMP only if your network is fitted for. 4.3.6.4 Enable SNMP-set Here you can activate SNMP-set protocol of Expert Power Control NET 8x 8210 / 8211. Use SNMP only if your network is fitted for. 4.3.6.
Expert Power Control NET 4x 8212 / 8213 4.3.7.2 Configuration 17 Trap Version Here you can choose between SNMP-traps standard v1 and v2c. Use SNMP only if your network is fitted for. More information about the SNMP functions of Expert Power Control NET 8x 8210 / 8211, you can find in chapter SNMP, on http://www.gude.info/wiki or ask our support team. 4.3.8 Configuration - Syslog Syslog messages are simple text messages transmitted to a syslog server using UDP.
Expert Power Control NET 4x 8212 / 8213 5 5.1 Configuration 18 Operation Switching at the device Expert Power Control NET 8x 8210 / 8211 disposes of two buttons: “select” and “ok”. By pushing “select”, the LED of Power Port 1 starts blinking which means that it is selected. By pushing the button again, the next Power Port is selected. If you want to change the switching state of the selected Power Port, push the “ok” button for two seconds.
Expert Power Control NET 4x 8212 / 8213 Operation 19 You can access Expert Power Control NET 8x 8210 / 8211 through the terminal program as soon as the status LED shines green. Choose the COM port that is connected to Expert Power Control NET 8x 8210 / 8211 and enter the following values for the serial interface: Bits per seconds Data bits Parity Stop bits Flow control 115200 8 none 1 none If you do not use HyperTerminal, please make sure that the terminal program supports VT100 commands.
Expert Power Control NET 4x 8212 / 8213 Operation Hybrid sensor 7002 Temperature sensor 7001 Cable length ˜ 2m Connection PS2 Measurement -10°C bis +70°C bei ±2°C (maximal) und ±1°C (typisch) Cable length ˜ 2m Connection PS2 Measurement (-40 bis +80 Grad, +- 0,5Grad/ Feuchte 0-100% +-3%) Hybrid sensor 7002 20
Expert Power Control NET 4x 8212 / 8213 6 6.1 Operation 21 Features Bootloader mode To activate the bootloader mode of Expert Power Control NET 8x 8210 / 8211 the select button must be pushed while restarting the device. In bootloader mode it is possible to disable the password protection, to update the firmware and to restore the default settings by running the program GBL_Conf.exe. If the device runs already, press the buttons "select" and "ok" for three seconds.
Expert Power Control NET 4x 8212 / 8213 7 Features 22 Support More information, current drivers and software can be found on http://www.gude.info. In case of further questions, about installation or operation of Expert Power Control NET 8x 8210 / 8211, please have look at www.gude.info/wiki or do not hesitate to contact our support (mail@gude.info).