Spezifikationen
ipacl filter {ipacl_num} set "{dns_name}"
sets IP filter {ipacl_num}
ipacl filter {ipacl_num} show
shows IP filter {ipacl_num}
linesensor
enters cmd group "linesensor"
linesensor all {field_list} show
shows energy sensors according field list of all line
sensors
5
linesensor {line_num} {energy_sensor} value show
shows energy sensor of given line
5
linesensor {line_num} counter reset
resets energy metering counter
linesensor {line_num} label set "{name}"
sets line meter to label
linesensor {line_num} label show
shows label of line meter
linesensor {line_num} {energy_sensor} events set
{OFF=0|ON=1}
enables events on/off
linesensor {line_num} {energy_sensor} events
show
shows if events are enabled
linesensor {line_num} {energy_sensor} events ty-
pe set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5}"
enables different event types
linesensor {line_num} {energy_sensor} events ty-
pe show
shows what event types are enabled
linesensor {line_num} {energy_sensor} maxval set
{float}
sets maximum value for line meter
linesensor {line_num} {energy_sensor} maxval
show
shows maximum value for line meter
linesensor {line_num} {energy_sensor} minval set
{float}
sets minimum value for line meter
linesensor {line_num} {energy_sensor} minval
show
shows minimum value for line meter
linesensor {line_num} {energy_sensor} hyst set
{float}
sets hysterese value for line meter
linesensor {line_num} {energy_sensor} hyst show
shows hysterese value for line meter
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
sets Port for Power Port Switching actions
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
shows Port for Power Port Switching actions
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
sets Port state for Power Port Switching actions
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
shows Port state for Power Port Switching actions
linesensor {line_num} events set {OFF=0|ON=1}
LEGACY - enables events on/off
L
linesensor {line_num} events show
LEGACY - shows if events are enabled
L
linesensor {line_num} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5}"
LEGACY - enables different event types
L
linesensor {line_num} events type show
LEGACY - shows what event types are enabled
L
linesensor {line_num} maxval set {float}
LEGACY - sets maximum value for line meter
L
linesensor {line_num} maxval show
LEGACY - shows maximum value for line meter
L
linesensor {line_num} minval set {float}
LEGACY - sets minimum value for line meter
L
linesensor {line_num} minval show
LEGACY - shows minimum value for line meter
L
linesensor {line_num} hyst set {float}
LEGACY - sets hysterese value for line meter
L
linesensor {line_num} hyst show
LEGACY - shows hysterese value for line meter
L
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
port set {port_num}
LEGACY - sets Port for Power Port Switching acti-
ons
L
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
port show
LEGACY - shows Port for Power Port Switching
actions
L
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state set {OFF=0|ON=1|DISABLED=2}
LEGACY - sets Port state for Power Port Swit-
ching actions
L
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state show
LEGACY - shows Port state for Power Port Swit-
ching actions
L
linesensor beeper set {OFF=0|ON=1}
enables beeper for line meter alarms
linesensor beeper show
shows if beeper for line meter alarms is enabled
modbus
enters cmd group "modbus"
modbus enabled set <off=0/on=1>
enables Modbus TCP support
modbus enabled show
shows if Modbus is enabled
modbus port set <ip_port>
sets Modbus TCP port