Datasheet
Remote Monitoring Sytems & LAN Sensors
04/2019
mail@gude.info
www.gude.info
shop.gude.info
GUDE Systems GmbH
Von-der-Wettern-Str. 23
51149 Koeln
•
Germany
T +49.221.912 90 97
F +49.221.912 90 98
new
84
IPv6
HTTPS
SSL
SNMPv3
Telnet
Modbus TCP
Order code Product Feature Power supply
2302-1 Expert Net Control 2302-1 4 switchable outputs, 8 passive signal inputs, 1 sensor port 230 V AC or 24 V DC
7101 Temperature Sensor 7101 Cable sensor with splash-proof sensor head (IP64), RJ45 connector, -20°C to +80°C,
cable ca. 2.3 m
7104 * Temperature Sensor 7104 Cable sensor, RJ45 connector, -20°C to +80°C, cable ca. 2.3 m
7105 * Temp., Humidity Sensor 7105 Cable sensor, RJ45 connector, -20°C to +80°C, 0-90% humidity, cable ca. 2.3 m
7106 * Temp., Humidity, Air pressure
Sensor 7106
Cable sensor, RJ45 connector, 20°C to +80°C, 0-90% humidity, 300-1100 hPa,
cable ca. 2.3 m
* Sensors also available with calibrated temperature range: 7104-2, 7105-2, 7106-2
7201 Temperature Sensor 7201 Box case with RJ45 socket, -20°C to +80°C
7202 Temp./Humidity Sensor 7202 Box case with RJ45 socket, -20°C to +80°C, 0-90% humidity
7311 Optical Smoke Detector 7311 Overhead installation (d=100 mm), screw terminal NO or NC
7312 Thermal Smoke Detector 7312 Overhead installation (d=100 mm), screw terminal NO or NC
7313 Leakage Point Sensor 7313 13 mm two-tined, detects ooding, 4-core wire (2.5 m)
7902 DIN Rail Power Supply Unit 7902 Power supply unit for DIN rail, 230 VAC / 12 VDC 1250 mA (not included in delivery)
7940 Comb. Signaling Device 7940 Optical/acoustic alarm device, 100 dB sound pressure, 3-core connection cable (0.4 m)
Expert Net Control 2302-1
Remote I/O System with 4 switchable relay outputs and 8 passive signal inputs for DIN-rail mounting
• SNMPv1, v2c, v3 (Get/Traps)
• TLS 1.0, 1.1, 1.2
• Radius and Modbus TCP support
• Configuration and control via Telnet
• IP Access Control List
• Android and iOS app Gude Control allows access from anywhere
• Low internal power consumption, typ. 2 W
• Developed and manufactured in
Germany
Electrical Connections
• Terminal clamps for power supply
with 230 V AC or 24 V DC
• 4 switchable outputs (terminal
clamp)
• 8 passive signal inputs (terminal
clamp)
• Ethernet connector RJ45
(10/100 Mbit/s)
• Sensor connector RJ45 for optional
sensors or serial interface (RS232)
Technical Details
• LxHxD: 10.5 x 7 x 9 cm
• Weight: ca. 300 g
• Operating temperature: 0-50 °C
• Storage temperature: -20 - 70 °C
• Relative humidity: 0 - 95 % (non-condensing environment)
Features
• 4 switchable, potential-free relay ouputs, switching voltage
230 V AC 16 A / 24 V DC, 10 A
• All relay outputs individually switchable directly on the device,
via HTTPS or command line tool
• Status and Power-up delay (0...9999 seconds) adjustable
individually for each output after power blackout
• Simultaneous power-up of multiple outputs prevented
by latency time of 1 second
• Switching of relay outputs dependent on
sensor threshold or inputs
possible
• Programmable turn-on/turn-
o sequence
• 4-channel watchdog to
monitor connected
consumers (ICMP/TCP)
• Bicoloured LEDs on front
panel display status informa-
tion of inputs/outputs
• 8 passive signal inputs for
monitoring NO and NC devices,
e.g. door contacts, smoke detec-
tors etc.
• Interface for optional sensor for envi-
ronmental monitoring (temperature,
humidity and air pressure)
• Messages by e-mail, Syslog and SNMP traps
depending on threshold values of sensor
metering and signal input as well
• Power supply also via external DIN rail unit 7902 possible
(not included in delivery)
• Comfortable conguration by web browser, Windows or Linux
tool
• Firmware update via Ethernet during operation
• IPv6-ready
• HTTP/HTTPS, e-mail (SSL, STARTTLS), DHCP, Syslog