User Manual
24
Expert Power Control 1202/1292
© 2018 Gude Analog- und Digitalsysteme GmbH
Operating
· 6 bars - approx. 100%
2.4.1
SMS
2.4.1.1
SMS Commands
Description of the SMS format to send commands to the device:
Format
%[cmd-name] [param 1] [...] [param N] {param 1} {...} {param N}
[param x] = mandatory parameter
{param x} = optional paramater
If activated, a port code or master code will be required. Entering these codes is initi-
ated by p (for Port code) or m (for Master code).
2.4.1.1.1 Powerport: Query Power Port State
Format
%port state [portnumber] {Portcode/Mastercode}
Command:
Request of status of Power Port 1, Portcode 1111
%port state 1 p1111
Answer:
Hostname: EPC-1292
Power Port state: Port 1 is Off
Credit: 130.50 Eur
Temp. 1: 25.8 C
2.4.1.1.2 Powerport: Simple Switching
Format
%port [on, off, toggle] [portnumber] {Portcode/Mastercode}
Examples:
Switch off Power Port 2, Mastercode 2222
%port off 2 m2222
Toggle Power Port 8, Portcode 1238
%port toggle 8 p1238
Reset Power Port 6, Portcode 0123
%port reset 6 p0123
Switch on Power Port 1, without Portcode
%port on 1
Answer (example):
Device name: epc007
Power switch: Port 1 off -> on