Product Manual
Indoor Hanger Bracket Assembly:
A Stacker Bracket System may also be installed in indoor applications. For indoor applications, the Indoor
Hanger Bracket MUST be used in place of the Top Clamp and Support Bracket assembly. After assembling the
Indoor Hanger Bracket according to the following instructions, follow the same installation procedure as for
the Stacker Bracket System.
1. Installation of 3’, 2” x 4” Support Brace at bottom of Indoor Hanger Bracket is not needed; the Support
Brace is replaced by the included Outrigger component of the Indoor Hanger Bracket.
2. Installation of the Top Clamp is not needed; the Top Clamp is replaced by the included Rail Clamp
component of the Indoor Hanger Bracket.
3. Prior to any other installation work, complete the following assembly instructions for the Indoor Hanger
Bracket. Each Indoor Hanger Bracket is assembled from one each of the following components:
Rail Clamp
Hanger Bracket
Outrigger
Hanger Bracket Post
To Assemble:
1. Insert Outrigger into bottom of Hanger Bracket. Secure with provided fastener. During installation of system,
Outrigger MUST be positioned so it crosses a minimum of three wall studs.
2. Insert Hanger Bracket Post into top of Hanger Bracket. Secure with provided fastener. Ensure all Hanger
Bracket Posts are assembled so that the entire system will be on an even plane, and that no Hanger Brackets
will be installed in front of windows or other open wall spaces.
3. Insert Rail Clamp into Hanger Bracket Post. Secure with provided fastener. Ensure that Rail Clamp “tooth” is
positioned towards railing on which Indoor Hanger Bracket is to be installed. Ensure Rail Clamp is sized in
accordance with railing.
4. Ensure entire Indoor Hanger Bracket system will sit flush against wall and railing.
5. Ensure all components of entire Indoor Hanger Bracket system are fully secured and properly assembled,
and then proceed with the installation or remainder of the system.
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
11