Product Name: Stacker Bracket System Part #: 61128; 61129; 61133; 61038; 61142; 61074; 61075; 61076; 61144; 61146; 61147; 61148; 61149 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 2 Components and Specifications 2-3 Installation and Use 4-12 Maintenance, Cleaning, and Storage 13 Inspection 13 Inspection Log 13 Safety
Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M and OSHA 1910 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state-specific regulations. Consult regulatory agencies for more information on fall protection systems and associated components.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 Product Specific Applications ! WARNING Use of equipment in unintended applications may result in serious injury or death. NEVER make any connections to guardrail systems. Fall Prevention: Stacker Bracket System may be used in Fall Prevention applications ONLY.
Guardian Fall Protection End Rail (#61228): Toeboard Attachment (#61142): 3 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com Lowering Strap Stacker Bracket Assembly 6305 S. 231st St.
www.guardianfall.com Installation and Use Prior to installation, plan your system: Support Brackets and Indoor Hanger Brackets MUST be spaced no more than 8’ apart. 1. Inspect and ensure the functionality of all components of the Stacker Bracket System, and the integrity of the structure to which it will be attached. 2. Define a perimeter around the building on which the Stacker Bracket System is to be used.
1. On 3’ long, 2” x 4” Support Brace, mark desired Support Bracket attachment location, making sure Support Bracket will cross at least three wall studs at selected installation location, even at sheer areas. 2. Nail selected 2” x 4”, 3’ Support Brace to Support Bracket at layout mark. DO NOT drive nail flush, as it must be removed during disassembly. Support Bracket might not always be centered on Support Brace. DO NOT nail Support Brace to wall.
www.guardianfall.com Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 Top Clamp Support Bracket Top Clamp Peg installation hole Top Clamp Peg Sheathed Threaded Bolt installation hole Sheathed Threaded Bolt Eyebolt 4. If Toeboards are required, install all Toeboard Attachments over Support Bracket Guardrail Post installation locations. Toeboard Attachment “foot” must face in towards wall.
Flush with rail and wall 7. Turn Top Clamp Eyebolt until snug. Use a ratchet to finish tightening until Eyebolt is two full turns past snug. NEVER use an impact wrench with this system. www.guardianfall.com Guardian Fall Protection 8. Insert Top Clamp Hitch Pin through hole in Top Clamp Peg, which has been inserted through Support Bracket. phone: (800) 466-6385 fax: (800) 670-7892 6. Hang Top Clamp and Support Bracket assembly over rail at selected installation location.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection 9. Install all remaining Top Clamp and Support Bracket assemblies. 10. At sheer wall locations, a Lowering Strap should be secured to Support Bracket as shown. Hang Lowering Strap over top of railing and secure. Lowering Strap is used during disassembly. Rungs face in towards rail 11. Install all Guardrail Posts from a secured ladder.
! WARNING Scaffold Planks and lumber Guardrails MUST overlap a MINIMUM 12” on each end. 15. Complete entire run of Scaffold Planks and Guardrails. Ensure overlapping Scaffold Planks and Guardrails are lapped in a continuous direction. Continuous lapping simplifies the disassembly process. 16. If Toeboards are required, attach 2” x 4” lumber Toeboards with a compatible nail or screw at all Toeboard Attachment locations. 2” x 4” Toeboard Compatible nail/screw at Toeboard Attachment location 9 www.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 17. Install End Rails at all system run termination points. Bottom of End Rail connects to Guardrail Post below the middle rung. Insert top of End Rail fully into top of Guardrail Post. See following image of a fully installed Stacker Bracket System (with a run termination requiring an End Rail): Guardian Fall Protection 6305 S. 231st St.
2. Installation of the Top Clamp is not needed; the Top Clamp is replaced by the included Rail Clamp component of the Indoor Hanger Bracket. 3. Prior to any other installation work, complete the following assembly instructions for the Indoor Hanger Bracket. Each Indoor Hanger Bracket is assembled from one each of the following components: Rail Clamp Hanger Bracket Post Hanger Bracket Outrigger To Assemble: 1. Insert Outrigger into bottom of Hanger Bracket. Secure with provided fastener.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Rail Clamp Hanger Bracket Post Hanger Bracket Outrigger Prior to Disassembly: Ensure all necessary carpentry is complete, including: 1) All roof vents and frieze blocks installed. 2) All fascia completed. 3) All roof sheeting and railing done. Holes cut for heat as applicable. 4) Fireplace stacks, pop-outs, skylights, dormers, and all other protrusions from surface are complete.
Cleaning after use is important for maintaining the safety and longevity of Stacker Bracket System. Remove all dirt, corrosives, and contaminants from Stacker Bracket System before and after each use. If Stacker Bracket System cannot be cleaned with plain water, use mild soap and water, then rinse and wipe dry. NEVER clean Stacker Bracket System with corrosive substances.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Safety Information ! WARNING Failure to understand and comply with safety regulations may result in serious injury or death. Regulations included herein are not all-inclusive, are for reference only, and are not intended to replace a Competent Person’s judgment or knowledge of federal or state standards. Do not alter equipment. Do not misuse equipment.
OR Stacker Bracket Top Clamp Part #: 61146 Date of manufacture: Compliant with OSHA 1910 and 1926 regulations. 1-800-466-6385 6305 S. 231st St., Kent, WA 98032 Made in China Follow the manufacturer’s instructions included with the equipment at time of shipment from the manufacturer. End Rails REQUIRED at EVERY Stacker Bracket run termination. www.guardianfall.com 6305 S. 231st St. Kent, WA 98032 1-800-466-6385 Stacker Bracket End Rail Part #: 61228 Compliant with OSHA 1910 and 1926 regulations.