Product Name: Arc-O-Pod Part #: 15030; 20001; 20004 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 2 Limitations 2-3 Components and Specifications 4 Installation and Use 5-7 Maintenance, Cleaning, and Storage 8 Inspection 8 Inspection Log 9 Safety Information 10 Labels 11
Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1-2007, and ANSI A10.32-2012 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state-specific regulations. Consult regulatory agencies for more information on fall protection systems and associated components.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Product Specific Applications ! WARNING Use of equipment in unintended applications may result in serious injury or death. Maximum 1 attachment per connection point.
Two connectors to same D-ring. NO. Connector directly to webbing. NO. Incompatible or irregular application, which may increase risk of roll-out. NO. Connector directly to horizontal lifeline. NO. Two or more snap hooks or carabiners connected to each other. NO. Correct Anchorage Positioning: This chart details allowable working zones required to reduce risk of swing falls and improper side loading. ALWAYS adhere to information specified by chart.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 Components and Specifications Guardian Fall Protection requires the Arc-O-Pod be used with a compatible SRL certified for use in Rescue/Confined Space applications, such as the 3-Way SRL (part #s 10974 and 10981). To mount fall protection equipment (SRL or winch) to Arc-O-Pod, a bracket designed to be used in combination with the SRL/winch is required.
Arc-O-Pod Set Up: * The Arc-O-Pod is easier to set up with two workers. If setting up system alone, complete steps 1 - 3 with Arc-O-Pod lying on ground. 1. Hold the collapsed Arc-O-Pod vertically with its feet on the ground. Remove Detent Pins from top of Arc-O-Pod. 2. Fully spread legs of Arc-O-Pod and replace Detent Pins removed in Step 1 to secure Adjustable Legs in an outward position. 3. Remove all Locking Pins from Arc-O-Pod Adjustable Legs. Fully extend Adjustable Legs.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 3-Way SRL Set Up: NEVER use 3-Way SRL for material hoisting or for routine personnel hoisting; doing so may result in increased wear of internal components. 3-Way SRL should only be used in personnel hoisting for the purposes or rescue/retrieval (to raise or lower a worker that has experienced a fall). For routine personnel or material hoisting, always use an independent winch, such as Guardian’s Rescue Winch (part # 15028).
3. Remove Detent Pin at Arc-O-Pod Pulley. Release sufficient amount of lifeline cable and run cable over Arc-O-Pod Pulley and down through top of Arc-O-Pod, so that it hangs over confined space entry location. Re-insert Detent Pin to ensure cable will stay in line with Pulley. www.guardianfall.com Guardian Fall Protection 4. Attach complete and compatible PFAS to 3-Way SRL snap hook. All PFAS equipment must be selected and deemed compatible with Arc-O-Pod and 3-Way SRL by a Competent Person.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Maintenance, Cleaning, and Storage If Arc-O-Pod fails inspection in any way, immediately remove it from service, and contact Guardian to inquire about its return or repair. Cleaning after use is important for maintaining the safety and longevity of Arc-O-Pod. Remove all dirt, corrosives, and contaminants from Arc-O-Pod before and after each use.
Product lifetime is indefinite, as long as it passes pre-use and Competent Person inspections. User must inspect prior to EACH use. Competent Person other than user must complete formal inspection at least every 6 months. Competent Person to inspect and initial. This inspection log must be specific to one Arc-O-Pod. Separate inspection logs must be used for each Arc-O-Pod. All inspection records must be made visible and available to all users at all times. Guardian Fall Protection 6305 S. 231st St.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Safety Information ! WARNING Failure to understand and comply with safety regulations may result in serious injury or death. Regulations included herein are not all-inclusive, are for reference only, and are not intended to replace a Competent Person’s judgment or knowledge of federal or state standards. Do not alter equipment. Do not misuse equipment.
Arc-O-Pod Part #: 15030 Date of Manufacture: Prior to use, read and understand all manufacturer's instructions provided with equipment at time of shipment from manufacturer. Compliant with OSHA 1910, OSHA 1926 Subpart M, ANSI Z359.1-07, and ANSI A10.32.12. Rated for one worker, or two workers during assisted rescue. Each worker must attach to a separate connection point. Worker capacity range (including all equipment): 130-310 lbs. Materials: Powder-coated steel and aluminum.