Product Manual

Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
5
Installation and Use
1. All PFAS components must be selected and deemed compatible with Diablo 2.5 Cable SRL-LE by Competent
Person.
2. Ensure structure to which Diablo 2.5 Cable SRL-LE is to be attached, and on which work is to be performed,
is free of all hazards, including, but not limited to, debris, rot, rust, sharp or abrasive edges and surfaces, and
hazardous materials.
3. Eliminate or minimize all risk of swing fall hazard.
4. Ensure 100% tie-off will be maintained at all times, which may require the use of a back-up or
supplementary fall protection system.
5. Always minimize lifeline contact with sharp or abrasive edges and surfaces.
To install Diablo 2.5 Cable SRL-LE to harness:
1. Compress and hold both release buttons on SRL Bracket and slide pin to open position. Do not attempt to
open or otherwise modify bracket that is connected to Diablo 2.5 Cable SRL-LE.
Release
buttons
2. At web loop immediately beneath harness dorsal D-ring, slide SRL Bracket pin through loop and lock closed.
It may be necessary to slightly loosen web loop to accommodate pin. Always re-tighten web loop after install.
Depending on SRL Bracket design, either ensure green indicator IS fully visible, or that red indicator
IS NOT visible.
Note: With Diablo 2.5 Cable SRL-LE attached to harness as shown, it is permitted to connect a separate
connecting device to the harness dorsal D-ring. However, never work with more than one connecting device
attached to an anchorage connector at any time.