Product Manual

Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
7
Maintenance, Cleaning, and Storage
If Diablo 2.5 Cable SRL-LE fails inspection in any way, immediately remove it from service and contact
Guardian.
Cleaning after use is important for maintaining the safety and longevity of Diablo 2.5 Cable SRL-LE. Remove all
dirt, corrosives, and contaminants from Diablo 2.5 Cable SRL-LE before and after each use. If Diablo 2.5 Cable
SRL-LE cannot be cleaned with plain water, use mild soap and water, then rinse and wipe dry. NEVER clean
Diablo 2.5 Cable SRL-LE with corrosive substances.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals,
or other degrading elements.
SRL-LE Additional Use Instructions:
ALWAYS adhere to the following warnings and specifications when using SRL-LEs.
!
WARNING
Setback Distance
Image 1 Image 2
Leading Edge
X≤90°
X≥90°
Diablo 2.5 Cable SRL-LEs are tested and certified for horizontal use over a steel edge without burrs. Diablo
Cable SRL-LEs may be used over similar surfaces, such as metal sheeting or other steel formations.
The allowable angle of redirection of the lifeline portion of Diablo 2.5 Cable SRL-LEs at the leading edge of a
fall hazard MUST be at least 90° (see Image 1).
Anchor point MUST be situated no lower than the leading edge of applicable fall hazard(s).
Prior to use, a Competent Person MUST calculate adequate fall clearance (see pg. 3).
ALWAYS attach to anchorage connector that will allow for required setback distance (see Image 2).
Setback distance: As determined by product testing, Guardian Fall Protection Diablo 2.5 Cable SRL-LEs
are not required to be setback any specific distance from the leading edge of applicable fall hazard(s).
Diablo 2.5 Cable SRL-LE may be used in combination with horizontal lifelines. All installation, set-up, and use
of horizontal lifelines must be done under the supervision of a Qualified Person.
NEVER work on the far side of an opening that is opposite the Diablo 2.5 Cable SRL-LE anchorage point.
In the event of a fall over the edge, special rescue measures may be necessary. Always account for use of
Diablo Cable SRL in job site rescue plan developed by job site Competent Person.