Product Manual

Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
6
SRL-LE Additional Use Instructions:
ALWAYS adhere to the following warnings and specifications when using SRL-LEs.
!
WARNING
Setback Distance
Image 1 Image 2
Leading Edge
X≤90°
X≥90°
Diablo Cable Tie-Back SRL-LEs are tested and certified for horizontal use over a steel edge without burrs. Diablo
Cable Tie-Back SRL-LEs may be used over similar surfaces, such as metal sheeting or other steel formations.
The allowable angle of redirection of the lifeline portion of Diablo Cable Tie-Back SRL-LEs at the leading edge
of a fall hazard MUST be at least 90° (see Image 1).
Anchor point MUST be situated no lower than the leading edge of applicable fall hazard(s).
Prior to use, a Competent Person MUST calculate adequate fall clearance (see pg. 3).
ALWAYS attach to anchorage connector that will allow for required setback distance (see Image 2).
Setback distance: As determined by product testing, Guardian Fall Protection Diablo Cable Tie-Back
SRL-LEs are not required to be setback any specific distance from the leading edge of applicable fall
hazard(s).
Diablo Cable Tie-Back SRL-LE may be used in combination with horizontal lifelines. All installation, set-up, and
use of horizontal lifelines must be done under the supervision of a Qualified Person.
NEVER work on the far side of an opening that is opposite the Diablo Cable Tie-Back SRL-LE anchorage point.
In the event of a fall over the edge, special rescue measures may be necessary. Always account for use of
Diablo Cable Tie-Back SRL-LE in job site rescue plan developed by job site Competent Person.
4. For Dual-Leg Kit, only work with one leg attached, except when transitioning between anchor points. When
transitioning between anchor points, first connect second leg to applicable anchor point, then disconnect other
leg from previous anchor point prior to beginning any work. Always ensure 100% tie-off is maintained.