Product Manual

Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
2
Product Specific Applications
Restraint: Diablo Cable Tie-Back SRL-LEs may be used in Restraint applications. Restraint systems
prevent workers from reaching the leading edge of a fall hazard. Always account for fully
deployed length of lanyard/SRL. Structure must withstand loads applied in the directions
permitted by the system of at least 1,000 lbs. No free fall is permitted. Restraint systems may
only be used on surfaces with slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal,
Chest, Side, Shoulder.
!
WARNING
Use of equipment in unintended applications may result in serious
injury or death. Maximum 1 attachment per connection point.
Personal Fall Arrest: Diablo Cable Tie-Back SRL-LEs may be used in Personal Fall Arrest
applications as a component of a MAXIMUM 1 Personal Fall Arrest System (PFAS). Structure must
withstand loads applied in the directions permitted by the system of at least 5,000 lbs. Applicable
D-ring: Dorsal.
• Free fall, LE Use: Maximum 5’.
• Free fall, non-LE Use: Maximum 2’.
For all applications, worker weight capacity range (including all clothing, tools, and equipment):
LE Use: 130-310 lbs.
Non-LE Use: 130-420 lbs.
Limitations
Fall Clearance: There must be sufficient
clearance below the anchorage connector
to arrest a fall before the user strikes the
ground or an obstruction. When calculating
fall clearance, account for a MINIMUM 2’
safety factor, deceleration distance, user
height, length of lanyard/SRL, harness
stretch, and all other applicable factors.
Diagram shown is an example fall
clearance calculation ONLY.
*Eliminate Swing Fall whenever
possible! If Swing Fall exists,
always account for additional
fall clearance.
Anchor Point
at Foot Level
Non-LE LE
Anchor Point
Level w/Dorsal D-ring
4.5’
to
8.5’
5’
2’
1.5’
Work Surface
2’
2’
2’
1.5’