Product Manual
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
4
Installation and Use
Setback Distance
Image 1 Image 2
Leading Edge
X≤90°
X≥90°
For use of Diablo Cable Big Block SRL in LE applications, refer to additional SRL-LE use instructions below.
ALWAYS avoid lifeline contact with sharp or abrasive edges and surfaces.
1. All components of the PFAS must be selected and deemed compatible with Diablo Cable Big Block SRL by
a Competent Person.
2. Ensure structure to which SRL is to be attached, and on which work is to be performed, is free of all hazards,
including, but not limited to, debris, rot, rust, sharp or abrasive edges and surfaces, and hazardous materials.
3. Connect Diablo Cable Big Block SRL housing to compatible anchorage connector, and connect snap hook to
applicable harness D-ring.
4. Ensure 100% tie-off will be maintained at all times, which may require the use of a back-up or
supplementary fall protection system.
SRL-LE Additional Use Instructions:
Diablo Cable Big Block SRLs are tested and certified for horizontal use over a steel edge without burrs. Diablo
Cable Big Block SRLs may be used over similar surfaces, such as metal sheeting, steel formations, concrete, or
wood.
The allowable angle of redirection of the lifeline portion of Diablo Cable Big Block SRLs at the leading edge of
a fall hazard MUST be at least 90° (see Image 1).
Anchor point MUST be situated no lower than the leading edge of applicable fall hazard(s).
Prior to use, a Competent Person MUST calculate adequate fall clearance (see pg. 2).
ALWAYS attach to anchorage connector that will allow for required setback distance (see Image 2).
Setback distance: As determined by product testing, Guardian Fall Protection Diablo Cable Big Block
SRLs are not required to be setback any specific distance from the leading edge of applicable fall
hazard(s).
Diablo Cable Big Block SRLs may be used in combination with horizontal lifelines. All installation, set-up, and
use of horizontal lifelines must be done under the supervision of a Qualified Person.
ALWAYS adhere to the following warnings and specifications when using SRL-LEs.
!
WARNING