To set the door number,
set address switches
4-8 as shown
NETWORK
Important !
Always Place Varistor
Across Lock Terminals
Door Release Button
A
B
A
Shield
FACTORY DEFAULT
This unit should be reset to its
factory default condition before
installation. To do this, power
the unit up with ALL switches in 
the OFF position. The two LED's
will illuminate for about 2 sec.
The correct switch settings may 
then be set.
For PIN only operation, set
switch 2 to the ON position
Door
Contact
LED2
LED1
DOOR I/O
Serial
Network
Entry/Exit Reader
General I/O
ACT 2000
This illustration shows wiring 
for a normally de-energised
lock. If a normally energised 
lock is required, use the 
N/C relay contacts.
Note: 
If the Mains Present or Door 
Contact inputs are not used, 
they should be linked to 0V
Entry Reader
RELAY
Tamper
Mains Preset
+12V
-DC
GIO4
GIO3
GIO2
GIO1
A
B
0V
A
B
0V
DTR
N/C C
AUX RLY 
N/ON/C C N/O
SENSE
CLOCK
DATA
+5V
0V
RED 
GREEN
RX
TX
0V
B
A
5A 250VAC
5A 30VDC
5A 250VAC
5A 30VDC
PUSH BUTTON
DOOR CONTACT
AUX
0V
OP2
OP3
1 2 3 4 5 6 7 8
W P 2 Address
2
On
On
4 5 6 7 8
On
03  OFF  OFF  OFF  ON    ON
04  OFF  OFF  ON    OFF  OFF
05  OFF  OFF  ON    OFF  ON
06  OFF  OFF  ON    ON    OFF
07  OFF  OFF  ON    ON    ON
08  OFF  ON    OFF  OFF  OFF
09  OFF  ON    OFF  OFF  ON
10  OFF  ON    OFF  ON    OFF
11  OFF  ON    OFF  ON    ON
12  OFF  ON    ON    OFF  OFF
13  OFF  ON    ON    OFF  ON
14  OFF  ON    ON    ON    OFF
15  OFF  ON    ON    ON    ON
16  ON    OFF  OFF  OFF  OFF
Power
Supply Unit
+12V
0V
30M
Total Length max 1.4km
For Clock & Data 
Readers, wire exit 
reader in parallel 
but leave it's 
sense line 
unconnected.
For Wiegand 
Readers, wire the 
DATA 0 of the exit 
reader to SENSE 
on the DS100
Network cable is single 
shielded twisted pair, 
Belden 9501 or similar
To next door
Shield
Shield
A
B
B
White
Green
Blue
Red
Black
Brown
Yellow
Orange
SENSE
CLOCK / DATA 1
DATA / DATA 0
+5v
0v
RED
GREEN
(Buzzer Ctrl)
Wiring for Clock and Data / Wiegand Reader
DOORS
Page 22 of 32
4
5
6
7
8
4
5
6
7
8
Required
Address
Required
Address
DS100 Door Station Installation
Technical Manuals Online! - http://www.tech-man.com