Keypad Operating & Installation Instructions
 ACT1000/2000 Operating Instructions Software Version 3.23-00 
Page 12 of 32 
Installer Menu 
System Settings  Operation  PIN Only 
PIN’s alone are used to gain access 
    Learn 
Users 1-1/2000 may use random coded cards 
    Ext. Keypad
1
Use external ACT20 keypad 
    KPD Release
1
✔
✔✔
✔ Key is exit button. 
    Exit PIN’s 
Exit PIN’s may be used in PIN only mode 
    Second Door
1
Second (Auxiliary) door enabled on ACT1000 
    User 
Limiting
2 
Prevent access if the user limit is reached 
    One-To-One 
Card numbers may be assigned to Users 1-
1000/2000 
    Multiple 
Users may have multiple cards 
  Display  Backlight 
Keypad backlight enabled 
    Keypad Beep 
Keypad beep enabled 
    Show Status 
Display current status of doors on LCD 
    Show Events 
Display events on LCD as they occur 
    Handshake 
Use handshake line when printing 
    Tech Bleep
2
Controller bleeps for technical fault 
  PIN Length 
Sets the length of user/group PIN codes. 
  Fire Doors 
Allows the definition of doors with fire override. 
  User Tracking
2
  Perimeter 
Define Perimeter doors 
    Antipassback 
Define Antipassback doors 
    Tracking Reset 
Set time for auto-reset (auto-logout) 
    User Limits 
Set user limits A & B 
  Outputs
2
  Door 1 
Define door 1 output special functions 
    Door 2 
Define door 2 output special functions 
Door Settings
*
  Operation  Push Button 
Door release button enabled 
    Lock Saver 
Relay de-energized as door opens 
    Chime 
Buzzer sounds as door opens 
    Guest Button 
!
!!
! on external keypad fires AUX/buzzer 
    Exit Always 
Timezones don’t apply to exit readers 
    Interlock 
Only one door may be open at any time. 
    Silent 
Confirmation tones disabled 
    Exit PIR 
Door stays open while Push Button closed 
    Failsafe 
Door relay is normally energised 
  Alarms  Door Forced 
Buzzer o/p active if door forced 
    Door Ajar 
Buzzer o/p active if door left ajar 
    Duress Alarm 
Buzzer o/p activated by duress code 
    Door Open 
Buzzer o/p active while door open 
    Acc. Granted 
Buzzer o/p when access granted 
    Acc. Denied 
Buzzer o/p when access denied 
1
 Feature present on ACT1000 only 
2
 Feature present on ACT2000 only 
*
 On ACT2000 you will first be required to select a door. 