Product Manual

Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
12
When used with an integral or compatible attached shock absorber extension, Velocity SRLs
with cable lifelines (part #s: 42000, 42001, 42002, 42003, 42004, and 42005) are tested and
certified for horizontal use over a steel edge without burrs. Velocity SRLs may be used over
similar surfaces, such as metal sheeting or other steel formations. Velocity SRLs with web
lifelines (part #s: 42006 and 42008) must NEVER be used in LE applications.
The allowable angle of redirection of the lifeline portion of Velocity SRLs at the leading
edge of a fall hazard MUST be at least 90° (see Image 1).
Anchor point MUST be situated no lower than the leading edge of applicable fall hazard(s).
Prior to use, a Competent Person MUST calculate adequate fall clearance (see pg. 7).
ALWAYS attach to anchorage connector that will allow for required setback distance (see
Image 2).
Setback distance: As determined by product testing, Guardian Fall Protection Velocity SRLs
MUST be installed a MINIMUM 6’ (1.8m) from the leading edge of applicable fall hazard(s).
Velocity SRLs may be used in combination with horizontal lifelines. All installation, set-up,
and use of horizontal lifelines must be done under the supervision of a Qualified Person.
NEVER work on the far side of an opening that is opposite the Velocity SRL anchorage
connector.
In the event of a fall over the edge, special rescue measures may be necessary. Always account
for use of Velocity SRLs in job site rescue plan developed by job site Competent Person.
ALWAYS adhere to the following warnings and specifications when using LE SRLs.
!
WARNING
Setback Distance
Image 1 Image 2
Leading Edge
X≤90°
X≥90°