Product Manual
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
4
Installation and Use
01500
01505
01506
01503
01511
Prior to installation:
1. Robe Grab for use in combination with compatible vertical lifeline (VLL). Ensure VLL on which Rope Grab is
to be installed is compliant with all applicable OSHA and ANSI regulations.
• Compatible with VLL with diameters from 1/2” - 5/8”.
!
WARNING
NEVER use with incompatible lifelines.
2. Eliminate all risk of lower end termination. Either ensure VLL will prevent user from striking next lower level
and that there is always adequate fall clearance, or that VLL will not reach the leading edge of any fall hazard
when used at its full length. NEVER tie knots in VLL, except at extreme bottom of lifeline in order to prevent
Rope Grab from detaching.
3. Eliminate or minimize all risk of swing fall.
Installation:
1. Open Rope Grab and position onto corresponding VLL, ensuring Positioning Arrow is pointed up towards
VLL anchorage.
2. Close gate fully around VLL and ensure gate is completely secured.
01507