Product Manual
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
5
Maintenance, Cleaning, and Storage
If Edge Angel SRL fails inspection in any way, immediately remove it from service, and contact Guardian to
inquire about its return or repair.
Cleaning after use is important for maintaining the safety and longevity of Edge Angel SRL. Remove all dirt,
corrosives, and contaminants from Edge Angel SRL before and after each use. If Edge Angel SRL cannot be
cleaned with plain water, use mild soap and water, then rinse and wipe dry. NEVER clean Edge Angel SRL with
corrosive substances.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals,
or other degrading elements.
Prior to EACH use, inspect Edge Angel SRL for deficiencies, including, but not limited to, corrosion, deformation,
pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, broken
stitching, fraying, bird-caging, and missing or illegible labels. IMMEDIATELY remove Edge Angel SRL from
service if defects or damage are found, or if exposed to forces of fall arrest.
Ensure that applicable work area is free of all damage, including, but not limited to, debris, rot, rust, decay,
cracking, and hazardous materials. Ensure that selected work area will support the application-specific
minimum loads set forth in this instruction manual. Work area MUST be stable.
At least every 6 months, a Competent Person other than the user must inspect Edge Angel SRL. Competent
Person inspections MUST be recorded in inspection log in instruction manual and on equipment
inspection grid label. The Competent Person must sign their initials in the box corresponding to the
month and year the inspection took place.
During inspection, consider all applications and hazards Edge Angel SRL has been subjected to.
Inspection
Edge Angel SRL may be used in combination with horizontal lifelines. All installation, set-up, and use of
horizontal lifelines must be done under the supervision of a Qualified Person.
NEVER work on the far side of an opening that is opposite the Edge Angel SRL anchorage point.
In the event of a fall over the edge, special rescue measures may be necessary. Always account for use of
Edge Angel SRL in job site rescue plan developed by job site Competent Person.
Setback Distance
Image 1 Image 2
Leading Edge
X≤90°
X≥90°