Product Manual

Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
4
Installation and Use
1. All PFAS components must be selected and deemed compatible with Edge Angel SRL by Competent Person.
2. Ensure structure to which Edge Angel SRL is to be attached, and on which work is to be performed, is free
of all hazards, including, but not limited to, debris, rot, rust, sharp or abrasive edges and surfaces, and
hazardous materials.
3. Eliminate or minimize all risk of swing fall hazard.
4. Edge Angel SRL may be used in either stationary or mobile applications. For stationary mode, attach Edge
Angel SRL carabiner to selected anchorage connector, and attach snap hook to applicable harness D-ring. Edge
Angel SRL must be used in stationary mode when used in LE applications (shock absorber end must be
connected to harness dorsal D-ring). For mobile mode, attach Edge Angel SRL carabiner to applicable harness
D-ring, and attach snap hook to selected anchorage connector.
5. Ensure 100% tie-off will be maintained at all times, which may require the use of a back-up or
supplementary fall protection system.
LE SRL Additional Use Instructions:
Edge Angel SRLs are tested and certified for horizontal use over a steel edge without burrs. Edge Angel SRLs
may be used over similar surfaces, such as metal sheeting or other steel formations.
The allowable angle of redirection of the lifeline portion of Edge Angel SRLs at the leading edge of a fall
hazard MUST be at least 90° (see Image 1).
Anchor point MUST be situated no lower than the leading edge of applicable fall hazard(s).
Prior to use, a Competent Person MUST calculate adequate fall clearance (see pg. 2).
ALWAYS attach to anchorage connector that will allow for required setback distance (see Image 2).
Setback distance: As determined by product testing, Guardian Fall Protection Edge Angel SRLs MUST be
installed a MINIMUM 6’ (1.8m) from the leading edge of applicable fall hazard(s).
ALWAYS adhere to the following warnings and specifications when using LE SRLs.
!
WARNING
ConnectorCarabiner
Connection Point
Cable
Housing
Lifeline Shock Absorber