Product Manual

Product Specific Applications
Personal Fall Arrest: Cross Arm Strap/Cable Choker may be used to support a
MAXIMUM 1 Personal Fall Arrest System (PFAS) for use in Fall Arrest applications.
Structure must withstand loads applied in the directions permitted by the system
of at least 5,000 lbs. Maximum free fall is 6‘, or up to 12’ if used in combination
with equipment explicitly certified for such use. Applicable D-ring: Dorsal.
Restraint: Cross Arm Strap/Cable Choker may be used in Restraint applications.
Restraint systems prevent workers from reaching the leading edge of a fall hazard.
Always account for fully deployed length of lanyard/SRL. Structure must withstand
loads applied in the directions permitted by the system of at least 1,000 lbs. No
free fall is permitted. Restraint systems may only be used on surfaces with slopes
up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal, Chest, Side, Shoulder.
!
WARNING
Use of equipment in unintended applications may result in serious
injury or death. Maximum 1 attachment per connection point.
For all applications: worker weight capacity range
(including all clothing, tools, and equipment) is 130-310 lbs.,
or up to 420 lbs. if used in combination with
equipment explicitly certified for such use.
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 USA phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
6