Product Manual
Compatibility: When making connections with Cross Arm Strap/Cable Choker, eliminate all
possibility of roll-out. Roll-out occurs when interference between a hook and the attachment
point causes the hook gate to unintentionally open and release. All connections must be
selected and deemed compatible with Cross Arm Strap/Cable Choker by a Competent Person.
All connector gates must be self-closing and self-locking, and withstand minimum loads of
3,600 lbs. See the following for examples of compatible/incompatible connections:
Connector
closed and
locked to
D-ring. OK.
Two or more
snap hooks or
carabiners
connected to
each other. NO.
Two connectors
to same
D-ring. NO.
Connector
directly to
horizontal
lifeline. NO.
Connector
to integral
lanyard.
NO.
Connector
directly to
webbing.
NO.
Application
that places
load on gate.
NO.
Incompatible
or irregular
application,
which may
increase risk
of roll-out. NO.
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 USA phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
8