7. Remove Detent Pin at Arc-O-Pod Pulley. Release sufficient amount of lifeline cable and run cable over
Arc-O-Pod Pulley and down through top of Arc-O-Pod, so that it hangs over confined space entry location.
Re-insert Detent Pin to ensure cable will stay in line with Pulley.
8. Attach complete and compatible PFAS to 3-Way SRL snap hook. All PFAS equipment must be selected and
deemed compatible with Arc-O-Pod and 3-Way SRL by a Competent Person.