Product Name: Arc-O-Pod Part #: 15030 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 2 Limitations 2-3 Components and Specifications 3 Installation and Use 4 Maintenance, Cleaning, and Storage 5 Inspection 5 Inspection Log 5 Safety Information 6 Labels 7
Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1-2007, and ANSI A10.32-2012 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state-specific regulations. Consult regulatory agencies for more information on fall protection systems and associated components.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 ! WARNING Use of equipment in unintended applications may result in serious injury or death. Maximum 1 attachment per connection point. Rescue/Confined Space: Arc-O-Pod may be used in Rescue/Confined Space applications. Rescue systems function to safely recover a worker from a confined location or after exposed to a fall. There are various configurations of Rescue systems depending on the type of rescue.
Two connectors to same D-ring. NO. Connector directly to webbing. NO. Incompatible or irregular application, which may increase risk of roll-out. NO. Connector directly to horizontal lifeline. NO. Two or more snap hooks or carabiners connected to each other. NO. Correct Anchorage Positioning: This chart details allowable working zones required to reduce risk of swing falls and improper side loading. ALWAYS adhere to information specified by chart.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Components and Specifications Guardian Fall Protection requires the Arc-O-Pod be used with a compatible SRL certified for use in Rescue/Confined Space applications, such as the 3-Way SRL (#10974). To mount the 3-Way SRL to the Arc-O-Pod, Guardian’s Mounting Bracket (#10983) is required.
3. Remove all Locking Pins from Arc-O-Pod Adjustable Legs. Fully extend Adjustable Legs. Reinstall Locking Pins with Adjustable Legs in fully extended positions. * This system is much easier to install with two workers. If setting up system alone, complete Steps 1-3 with Arc-O-Pod lying on ground. 4. Place Arc-O-Pod over confined space entry point.
www.guardianfall.com 1) Place Mounting Bracket over leg as shown, so 3-Way SRL snap hook will face up towards Arc-O-Pod Pulley. 2) Select desired height of 3-Way SRL on Arc-O-Pod leg, and place Mounting Bracket at location. 3) Install (2) provided Locking Pins through Mounting Bracket and Arc-O-Pod leg as shown. 4) Secure Locking Pins with connected hitch pins, and ensure Mounting Bracket is fully secured to Arc-O-Pod leg. 6.
www.guardianfall.com Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 8. Attach complete and compatible PFAS to 3-Way SRL snap hook. All PFAS equipment must be selected and deemed compatible with Arc-O-Pod and 3-Way SRL by a Competent Person. phone: (800) 466-6385 fax: (800) 670-7892 7. Remove Detent Pin at Arc-O-Pod Pulley. Release sufficient amount of lifeline cable and run cable over Arc-O-Pod Pulley and down through top of Arc-O-Pod, so that it hangs over confined space entry location.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Maintenance, Cleaning, and Storage If Arc-O-Pod fails inspection in any way, immediately remove it from service, and contact Guardian to inquire about its return or repair. Cleaning after use is important for maintaining the safety and longevity of Arc-O-Pod. Remove all dirt, corrosives, and contaminants from Arc-O-Pod before and after each use.
Product lifetime is indefinite, as long as it passes pre-use and Competent Person inspections. User must inspect prior to EACH use. Competent Person other than user must complete formal inspection at least every 6 months. Competent Person to inspect and initial. This inspection log must be specific to one Arc-O-Pod. Separate inspection logs must be used for each Arc-O-Pod. All inspection records must be made visible and available to all users at all times. Guardian Fall Protection 6305 S. 231st St.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Safety Information ! WARNING Failure to understand and comply with safety regulations may result in serious injury or death. Regulations included herein are not all-inclusive, are for reference only, and are not intended to replace a Competent Person’s judgment or knowledge of federal or state standards. Do not alter equipment. Do not misuse equipment.
Read and fully understand the manufacturer’s supplied instructions before using this product. It is the employers responsibility to train each employee on the usage of this product. Maximum user weight may not exceed 310lbs. 1) Inspect the entirety of the tripod for any signs of deformation or cracks. Do not use if the product reveals an unsafe condition. 2) Ensure all locking pins are in place before using. Call Guardian Fall Protection or your local distributor for replacement parts.