Product Manual
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
5
Maintenance, Cleaning, and Storage
If 2-Way Standing Seam Roof Clamp fails inspection in any way, immediately remove it from service, and
contact Guardian to inquire about its return or repair.
Cleaning after use is important for maintaining the safety and longevity of 2-Way Standing Seam Roof Clamp.
Remove all dirt, corrosives, and contaminants from 2-Way Standing Seam Roof Clamp before and after each
use. If 2-Way Standing Seam Roof Clamp cannot be cleaned with plain water, use mild soap and water, then
rinse and wipe dry. NEVER clean 2-Way Standing Seam Roof Clamp with corrosive substances.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals,
or other degrading elements.
Prior to EACH use, inspect 2-Way Standing Seam Roof Clamp for deficiencies, including, but not limited to,
corrosion, deformation, pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive
heating, alteration, and missing or illegible labels. IMMEDIATELY remove 2-Way Standing Seam Roof Clamp
from service if defects or damage are found, or if exposed to forces of fall arrest.
Ensure that applicable work area is free of all damage, including, but not limited to, debris, rot, rust, decay,
cracking, and hazardous materials. Ensure that selected work area will support the application-specific
minimum loads set forth in this instruction manual. Work area MUST be stable.
At least every 6 months, a Competent Person other than the user must inspect 2-Way Standing Seam Roof
Clamp. Competent Person inspections MUST be recorded in inspection log in instruction manual and on
equipment inspection grid label. The Competent Person must sign their initials in the box
corresponding to the month and year the inspection took place.
During inspection, consider all applications and hazards 2-Way Standing Seam Roof Clamp have been
subjected to.
Inspection
Inspection Log
If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE.
Date of First Use: __________________.
Product lifetime is indefinite as long as it passes pre-use and Competent Person inspections. User must
inspect prior to EACH use. Competent Person other than user must complete formal inspection at least
every 6 months. Competent Person to inspect and initial.
This inspection log must be specific to one 2-Way Standing Seam Roof Clamp. Separate inspection logs
must be used for each 2-Way Standing Seam Roof Clamp. All inspection records must be made visible
and available to all users at all times.