Installation and Use
Prior to installation, plan your system:
1. All PFAS equipment must be selected and deemed compatible with 2-Way Standing Seam Roof Clamp by a
Competent Person.
2. Eliminate or minimize all risk of swing fall hazards.
3. Ensure installation location and work surface are free of all damage, including, but not limited to, corrosion,
rot, rust ,debris, and sharp or abrasive edges and surfaces.
MINIMUM required substrate thickness: 24 gauge.
Installation:
1. 2-Way Standing Seam Roof Clamp is designed for use on a standing seam roof ONLY.
2. 2-Way Standing Seam Roof Clamp MUST be attached to a fully seamed panel and MUST be attached over a
clip that is bolted/screwed down.
3. 2-Way Standing Seam Roof Clamp must be positioned a minimum 4’ from leading edge(s) of fall hazard(s).
4. Hook clamp flange under selected roof seam. This must be done before bolts are tightened.
5. Tighten upper (2) bolts until snug, then tighten lower (2) bolts until snug.
6. Tighten upper (2) bolts to 50 ft./lbs., then tighten lower (2) bolts to 50 ft./lbs. Ensure 2-Way Standing
Seam Roof Clamp is fully secured to roof seam and no possibility exists for detachment.
7. Attach complete and compatible PFAS to 2-Way Standing Seam Roof Clamp O-ring.
Prior to installation, a Qualified Person must determine
2-Way Standing Seam Roof Clamp is compatible with roof seam.
!
WARNING