Third Party Verification Claim

INSPEC Test Report No: 2.16.05.18 Page 8 of 14
3.2.5 Dynamic performance test - Cold dry condition (maximum arrest force)
Specimens 2D03305 to 2D03307 were assessed.
During the dynamic performance test, the maximum arrest force of the specimens
were recorded as follows:
Specimen 2D03305 was 1338 pounds.
Specimen 2D03306 was 1399 pounds.
Specimen 2D03307 was 1272 pounds.
These values are less than the maximum 1,800 pounds permitted.
See Annex 1 for the plot of force versus time.
Pass
Pass
Pass
3.2.5 Dynamic performance test - Cold dry condition (deployment distance)
Specimens 2D03305 to 2D03307 were assessed.
During the dynamic performance test, the deployment distance of the specimens
were recorded as follows:
Specimen 2D03305 was 29.4 inches.
Specimen 2D03306 was 28.7 inches.
Specimen 2D03307 was 29.8 inches.
These values are less than the maximum 48 inches permitted.
Pass
Pass
Pass
3.2.5 Dynamic performance test - Hot dry condition (average arrest force)
Specimens 2D03308 to 2D03310 were assessed.
During the dynamic performance test, the average arrest force of the specimens
were recorded as follows:
Specimen 2D03308 was 718 pounds.
Specimen 2D03309 was 749 pounds.
Specimen 2D03310 was 728 pounds.
These values are less than the maximum 1,125 pounds permitted.
See Annex 1 for the plot of force versus time.
Pass
Pass
Pass
3.2.5 Dynamic performance test - Hot dry condition (maximum arrest force)
Specimens 2D03308 to 2D03310 were assessed.
During the dynamic performance test, the maximum arrest force of the specimens
were recorded as follows:
Specimen 2D03308 was 1006 pounds.
Specimen 2D03309 was 1120 pounds.
Specimen 2D03310 was 1098 pounds.
These values are less than the maximum 1,800 pounds permitted.
See Annex 1 for the plot of force versus time.
Pass
Pass
Pass