Third Party Verification Claim
INSPEC Test Report No: 2.16.05.18 Page 6 of 14
3.2.4 Dynamic performance test - Ambient dry condition (average arrest force)
Specimen 2D03002 to 2D03004 was assessed.
During the dynamic performance test, the average arrest force of the specimens
were recorded as follows:
Specimen 2D03002 was 810 pounds.
Specimen 2D03003 was 815 pounds.
Specimen 2D03004 was 809 pounds.
These values are less than the maximum 900 pounds permitted.
See Annex 1 for the plot of force versus time.
Pass
Pass
Pass
3.2.4 Dynamic performance test - Ambient dry condition (maximum arrest force)
Specimen 2D03002 to 2D03004 was assessed.
During the dynamic performance test, the maximum arrest force of the specimens
were recorded as follows:
Specimen 2D03002 was 1395 pounds.
Specimen 2D03003 was 1287 pounds.
Specimen 2D03004 was 1329 pounds.
These values are less than the maximum 1,800 pounds permitted.
See Annex 1 for the plot of force versus time.
Pass
Pass
Pass
3.2.4 Dynamic performance test - Ambient dry condition (deployment distance)
Specimen 2D03002 to 2D03004 was assessed.
During the dynamic performance test, the deployment distance of the specimens
were recorded as follows:
Specimen 2D03002 was 31.5 inches.
Specimen 2D03003 was 37.2 inches.
Specimen 2D03004 was 35.4 inches.
These values are less than the maximum 48 inches permitted.
Pass
Pass
Pass