Product Name: Temper Anchor Part #: 00455; 00458 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 2 Limitations 2-3 Components and Specifications 3 Installation and Use 4-5 Maintenance, Cleaning, and Storage 5 Inspection 5 Inspection Log 6 Safety Information 6-7 Labels 7
User Information Date of First Use: Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1-2007, and ANSI A10.32-2012 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state regulations if applicable.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Product Specific Applications ! WARNING Use of equipment in unintended applications may result in serious injury or death. Maximum 1 attachment per connection point. Personal Fall Arrest: Temper Anchor may be used to support a MAXIMUM 1 PFAS for use in Fall Arrest applications. Structure must withstand loads applied in the directions permitted by the system of at least 5,000 lbs.
Incompatible or irregular application, which may increase risk of roll-out. NO. Connector directly to horizontal lifeline. NO. Correct Anchorage Positioning: This chart details allowable working zones required to reduce risk of swing falls and improper side loading. ALWAYS adhere to information specified by chart.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Installation and Use MINIMUM substrate thickness: Wood: 3/4” CDX or better; Metal: 20g or better. Applicable roof pitches: 0/12 - 12/12. All fasteners MUST be fully embedded in substrate. Temper Anchor MUST install flush against substrate. NEVER install onto bare rafter or truss. All installation must be done under the supervision of a Competent Person. 1.
. Attach complete and compatible PFAS to Temper Anchor Connection Point. ! WARNING NEVER over-torque screws. Excessive torque will cause damage to screws and result in unsafe installation. Not for permanent installation applications. May be used in multiple installation applications. Always use new fasteners for each new installation. Removal of anchor from present installation location may cause warping or damage.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Inspection Log Date of First Use: __________________. Product lifetime is 5 years from Date of First Use, or, if not recorded, from Date of Manufacture, as long as it passes pre-use and Competent Person inspections. User must inspect prior to EACH use. Competent Person other than user must complete formal inspection at least every 6 months. Competent Person to inspect and initial.
NEVER use fall protection equipment of any kind to hang, lift, support, or hoist tools or equipment, unless explicitly certified for such use. www.guardianfall.com Training of Authorized Persons to correctly erect, disassemble, inspect, maintain, store, and use equipment must be provided by a Competent Person. Training must include the ability to recognize fall hazards, minimize the likelihood of fall hazards, and the correct use of personal fall arrest systems.