Product Name: Temper Anchor Part #: 00455 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 2 Limitations 2-3 Components and Specifications 3 Installation and Use 4-5 Maintenance, Cleaning, and Storage 5 Inspection 5 Inspection Log 6 Safety Information 6-7 Labels 7
User Information Date of First Use: Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.18-2017, and ANSI A10.32-2012 standards for fall protection. This product has been tested in compliance with the requirements of ANSI/ASSE Z359.7. Testing only covers hardware and does not extend to the anchorage or substrate to which this product is attached.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Product Specific Applications ! WARNING Use of equipment in unintended applications may result in serious injury or death. Maximum 1 attachment per connection point. Personal Fall Arrest: Temper Anchor may be used to support a MAXIMUM 1 PFAS for use in Fall Arrest applications. Structure must withstand loads applied in the directions permitted by the system of at least 5,000 lbs.
www.guardianfall.com Connector to integral lanyard. NO. Two connectors to same D-ring. NO. Connector directly to webbing. NO. Incompatible or irregular application, which may increase risk of roll-out. NO. Connector directly to horizontal lifeline. NO. Two or more snap hooks or carabiners connected to each other. NO. Correct Anchorage Positioning: This chart details allowable working zones required to reduce risk of swing falls and improper side loading.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Installation and Use MINIMUM substrate thickness requirements: Compatible roof pitch: • Wood: 3/4” (total combined). • Metal: 20g. • Concrete: 4” thick and 4,000 PSI. • Installed over roof peak: 0/12 - 12/12. • Installed on flat surface: 0/12 - vertical/sheer. Never install past sheer (such as on underside of beam or slab).
www.guardianfall.com Concrete install: - Use (8) fasteners (4 per side). Distribute fasteners evenly across Temper Anchor. Maintenance, Cleaning, and Storage If Temper Anchor fails inspection in any way, immediately remove it from service, and contact Guardian to inquire about its return or repair. Field serviceability testing is not required, and should not be done by the end user. Cleaning after use is important for maintaining the safety and longevity of Temper Anchor.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Inspection Log Date of First Use: __________________. Product lifetime is indefinite, as long as it passes pre-use and Competent Person inspections. User must inspect prior to EACH use. Competent Person other than user must complete formal inspection at least every 12 months. Competent Person to inspect and initial. This inspection log must be specific to one Temper Anchor.
NEVER use fall protection equipment of any kind to hang, lift, support, or hoist tools or equipment, unless explicitly certified for such use. www.guardianfall.com Training of Authorized Persons to correctly erect, disassemble, inspect, maintain, store, and use equipment must be provided by a Competent Person. Training must include the ability to recognize fall hazards, minimize the likelihood of fall hazards, and the correct use of personal fall arrest systems.