PX Control Panel User Manual Issue C
PX Control Panel User Manual – Issue C Contents CONTENTS ...............................................................................................................................................................................2 INTRODUCTION .....................................................................................................................................................................5 EVENT LOG........................................................................................
PX Control Panel User Manual – Issue C M ANAGED RESET ...............................................................................................................................................................20 TEST........................................................................................................................................................................................ 21 SOUNDER................................................................................................
PX Control Panel User Manual – Issue C SCHEDULE (PX80 & 500).................................................................................................................................................. 39 SET GROUP ........................................................................................................................................................................... 39 BYPASS..............................................................................................................
PX Control Panel User Manual – Issue C Introduction The PX Electronic Intruder Alarm System is designed to provide secure protection for the installation. The system is highly versatile, permitting individual systems to be installed and programmed to meet the particular security requirements of each installation. The system comprises a main control panel, normally located out of sight in a secure area, and at least one keypad.
PX Control Panel User Manual – Issue C User, Set group and Circuit Identification Each user, set group, and circuit can be programmed with a text description. An authorised user can change a user text descriptor. User Codes Each user of the system is identified by a unique code. This code can be a PIN code, an electronic key or proximity token. An electronic key can only be used on a keypad variant with an electronic key interface.
PX Control Panel User Manual – Issue C Electronic Keys A user PIN code can be replaced by an electronic key. To use the facility at least one keypad in the system must have the optional electronic key interface fitted. All Guardall electronic keys are manufactured with a unique code and duplicate keys cannot be obtained. Spare or replacement keys can be obtained from the installation company.
PX Control Panel User Manual – Issue C Menu Format User Menu 01=Unset 02=Set 03=Reset 04=Test 05=Engineer 06=Code 07=User 10=Log-Full 11=Log-Cct 12=Log-User 13=Log-KP 14=Log-Date 15=Log-Alarm 16=A/Log-Full 17=A/Log-User 18=A/Log-Door 20=Time 24=Holiday 25=Schedule 26=SetGroup 30=Bypass 31=KP Off 32=Chime 40=Print Text 42=Print Hols.
PX Control Panel User Manual – Issue C PX 18/34 Menu Layout The menu map shows all possible menu options and, where appropriate, sub menus. 01=Unset 02=Set 03=Reset 04=Test 05=Engineer 06=Code 07=User 10=Log-Full 11=Log-Cct 12=Log-User 13=Log-KP 14=Log-Date 15=Log-Alarm 16=A/Log Full 17=A/Log User 18=A/Log Door 20=Time 24=Holiday 25=Schedule 26=Set Group 30=Bypass 31=KP Off 32=Chime 40=Print Text 42=Print Hols.
PX Control Panel User Manual – Issue C PX 80/500 Menu Layout The menu map shows all possible menu options and, where appropriate, sub menus. 01=Unset 02=Set 03=Reset 04=Test 05=Engineer 06=Code 07=User 10=Log-Full 11=Log-Cct 12=Log-User 13=Log-KP 14=Log-Date 15=Log-Alarm 16=A/Log Full 17=A/Log User 18=A/Log Door 20=Time 24=Holiday 25=Schedule 26=Set Group 30=Bypass 31=KP Off 32=Chime 40=Print Text 42=Print Hols.
PX Control Panel User Manual – Issue C Invalid User Codes 12:00 Mon 27 Sep Incorrect Code If an incorrect user code is entered, the incorrect code message will be displayed for 4 seconds or until another key is pressed. If more than the programmed number of code attempts are made to enter a valid user code, the keypad will be locked out and the display will show Out of Service for a period of 5 minutes.
PX Control Panel User Manual – Issue C Not Available Message Where Used No Authority User tries to select an option that is not allowed with their programmed authority level. No Set Area User selects unset when all areas that can be unset from the keypad are already unset. Timer Control On User attempts to log on outwith the schedule times. No Unset Area User selects set when all areas that can be set from the keypad are already set. Set Area User attempts to access test when an area is set.
PX Control Panel User Manual – Issue C Help The system will display context sensitive help for menu and programming options. When the main menu is on display press the help button (?) to display information about the system. 02=Set 05=Eng The normal log on menu Press the ? button to display the customer help menu. Help Menu 0=Remote Service 1=Contract 2=Product Info Help Menu Remote Service The remote service option is only required if your alarm company offers this service.
PX Control Panel User Manual – Issue C Message Alarm Abort Setting Stopped Group Unset Cannot Set Unset Alarm Mult.Alarm Code Known Call Engineer Reset OK Set 4=Confirm Soak Cct Fails Reason User logs on within the alarm abort period (programmable option) User logs on during the setting exit period A group(s) is set and is programmed to automatically unset when a user logs on. The system cannot set, the reason(s) will then be displayed. An unset alarm has occurred, the details will then be displayed.
PX Control Panel User Manual – Issue C If automatic logon/unset is not configured then choose the unset option manually.
PX Control Panel User Manual – Issue C 01=Unset 05=Eng Press 01 to unset If more than 1 authorised group is set then the available options will be displayed. 1=Workshop 2=Office Choose the group to unset. The keypad may be configured to automatically log the user off from the system after unset. Unsetting from a keyswitch To unset an area from a keyswitch, turn the keyswitch to the unset position. The area under the control of the keyswitch will immediately unset.
PX Control Panel User Manual – Issue C Set Code-02 The system can be partitioned into a number of parts called set groups, each of which can be individually set. The programmed user authority level must allow setting and the programmed user area access will determine which set groups are available to a user. Setting can be started by: 1. 2. 3. 4. 5.
PX Control Panel User Manual – Issue C Automatic Setting The system may have been programmed by the installation engineer to automatically set all or parts of the system according to a pre-programmed schedule. The schedule will have been programmed to take into account the normal closing time, non-working days and holidays. The schedule may be configured for any set mode.
PX Control Panel User Manual – Issue C 4=Force Set Press the 4 button to try to force set. If the circuits in fault can be bypassed then the system will report the bypassed circuits and then prompt the user to confirm setting. Failure to Set after Exit Time If the group fails to set at the end of the exit period, the exit tone will change to warn the user that the system has not set. Log on to the keypad to display the fault condition(s).
PX Control Panel User Manual – Issue C Reset Code-03 The resetting method programmed by the alarm company engineer for each area and the system will depend on the particular security requirements of the area or system. There are 3 types of reset: 1. 2. 3.
PX Control Panel User Manual – Issue C Test Code-04 Each area of the system can be tested individually or all areas can be tested at the same time. The test time is limited to 1 hour. If the user does not end the test by the end of the test time then the panel will exit test mode automatically. When the test option is selected the area test menu will be displayed. Test Areas Menu Enter the area number to test (area 0 for the system).
PX Control Panel User Manual – Issue C All Tested - 22 -
PX Control Panel User Manual – Issue C When the panel exits test mode, either manually or automatically at the end of the test time then: 1. 2. 3. Any fire sensor still in alarm will give a normal alarm response. Circuits with a 24-hour response, which are still in alarm, will be temporarily bypassed. A warning will be displayed if any PA sensor is still in alarm.
PX Control Panel User Manual – Issue C Code-07 User Feature Max. Users Max. Security PX18 20 20 PX34 40 40 PX80 1000 100 PX500 1000 200 A manager user can change the name, user code and authority for any user except the engineer. To modify a user’s details enter the user number in the range 2-max users. The user menu will then be displayed. The user 2 configuration may only be changed by user 1 or user. Access system users be added quickly using the “Add User” menu option (50).
PX Control Panel User Manual – Issue C User Menu Code-2 Code For details of changing a code refer to the section on code change on page 23. The default user codes are shown in the table. Default Codes User Number PIN 2 0202 3-last user Off User Menu Code-3 Authority Users can be programmed with a number or options including authority level, area access and timed access. When the authority option is selected the user authority menu is displayed.
PX Control Panel User Manual – Issue C The menu options available to each authority level are shown in the table. Menu Option Code Text 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 18 20 24 25 26 30 31 32 40 42 50 51 52 53 54 55 71 73 86 87 89 Unset Set Reset Test Engineer Code User Log-Full Log-Cct Log-User Log-KP Log-Date Log-Alarm A/Log-Full A/Log-User A/Log-Door Time +/-75m Holiday Schedule Set Group Bypass KP Off Chime Print Text Print Hols.
PX Control Panel User Manual – Issue C displayed when logging on or, if there is only one set group available, setting will start when the user logs on.
PX Control Panel User Manual – Issue C User Authority Menu On/Off Schedule 1-2 (PX18/34) A user can be programmed with schedules 1 and/or 2 to control access times. The timer and holiday schedules may also be programmed. User Authority Menu On/Off Set Group 1-max If the Set Group option is on the user can be programmed any combination of set groups.
PX Control Panel User Manual – Issue C Off No expiry date is programmed, press enter to change - 29 -
PX Control Panel User Manual – Issue C Expiry Date Enter DDMMYYYY Enter the day, month and year. To delete an expiry date enter the day and month of 0000 and the current year. Logs The panel logs all events that occur in the system. All events stored in the event log are numbered in the range 0-65535. The event number is only used when printing the log. The event number will be the same even if the event is printed as part of a filtered log.
PX Control Panel User Manual – Issue C Logs Log-Full Code-10 Log-Cct Code-11 All logged events may be displayed or printed. Logs All logged events for a particular circuit number may be displayed or printed. Logs Log-User Code-12 All logged events for a particular user may be displayed or printed. Logs Log-KP Code-13 All logged events for a particular keypad may be displayed or printed. Logs Log-Date Code-14 All logged events for a particular date may be displayed or printed.
PX Control Panel User Manual – Issue C Logs Log Messages Log Text Alarm Anti mask Bat.Monitor Fail Battery Low Comm Fail Entry Alarm Fire Panel Tamper Personal Attack Rmt.
PX Control Panel User Manual – Issue C Log Text 230v Fault 230v OK Active Circuit Alarm (master shunt) Alarm Abort Auto Check Fail Auto Check OK Bypass Cannot set Cct Tested Changed Code Changed Code Changed Time Check Fuse Check Fuse Check Fuse Check Fuse Clear Code Clash Comm Acknowledge Comm Fail Comm Test Duress Alarm Engineer Reset Entry Started Failed Auto Set Fault Fault Fault Fault Fault Fault First code Head Count Isolate Isolate Key Set Req. Key Unset Req.
PX Control Panel User Manual – Issue C Log Text Knock Line Block Line Fault Event log only messages Additional Data Display Text Event Description Circuit nnn Cctnnn Circuit first knock NONE NONE SmartDial has reported a line blocked condition 1 - 50 volts not present NONE Communicator has reported a 2 - Line block test failure line fault 3 - No acknowledge from central station 4 - Main PCB LF input 5- SmartDial Fault Lockout Logged Off Logged On Managed Rst Marginal Mult.
PX Control Panel User Manual – Issue C Log Text Verify Alm Watchdog Event log only messages Additional Data Display Text Event Description Area n An A verified alarm has occurred NONE NONE Software watchdog active - 35 -
PX Control Panel User Manual – Issue C Note: If the software versions supports auxiliary PSUs then the following messages will be logged with a number: • • • • • Battery Low 230v Fault 230v OK Power Fail Bat.Monitor Fail The number represents the PSU device: Logged Number 0 1-max concs Max concs-max concs + max access modules Device Control Panel Concentrator number Access module number Access Denied Set Req. Unset Req.
PX Control Panel User Manual – Issue C Code-24 Holiday Feature Max. Holidays PX18 0 PX34 14 PX80 14 PX500 14 This option is used in conjunction with the programmable schedules. To program a holiday, select the holiday option from the main menu followed by the holiday number. The holiday menu will then be displayed. Holiday Holiday-x Start-DD:MM End-DD:MM Set Group-1 Options x=holiday number DD:MM DD:MM 1 – Max Set Groups Note: The holiday date format is day and month only.
PX Control Panel User Manual – Issue C Schedule (PX18 & 34) Feature Max. Schedules PX18 4 Code-25 PX34 8 A schedule can be used to: 1. 2. 3. 4. Auto set and unset parts of the system Control outputs Enable/disable keypads Enable/disable user access To program a schedule, select the schedule option from the main menu followed by the schedule number. The schedule menu will then be displayed. Schedule Schedule-x Start Time-00:00 Stop Time-00:00 Mon-Off Tue-Off ...
PX Control Panel User Manual – Issue C Code-25 Schedule (PX80 & 500) Feature Max. Schedules PX80 16 PX500 32 A schedule can be used to: 1. 2. 3. 4. Auto set and unset parts of the system Control outputs Enable/disable keypads Enable/disable user access To program a schedule, select the schedule option from the main menu followed by the schedule number. The day menu will then be displayed.
PX Control Panel User Manual – Issue C Bypass Code-30 The bypass option will only be available if a circuit(s) has been programmed as bypassable by the installation engineer. The bypass circuit option allows the user to bypass a circuit that is in a fault condition. When bypassed the alarm condition of a circuit is ignored. Circuit Number-x To bypass a circuit select the bypass option from the main menu, followed by the circuit number.
PX Control Panel User Manual – Issue C Printing Print Text Code-40 The print text option will print all text descriptors for users, circuits, set groups, and the company name. Printing Print Hols. The print holiday option will print all holiday periods.
PX Control Panel User Manual – Issue C Access Features The number of Access Modules that can be connected depends on the panel variant: Feature Access Modules PX18 2 PX34 2 PX80 16 PX500 32 The table shows the access features across the panel range. Feature Doors Panel Users Access Users User expiry dates Challenged user option User lock out from keypad Door lock/unlock from keypad Programmable unlock time Programmable Aux.
PX Control Panel User Manual – Issue C Code-50 Add User When the Add User option is selected, the first free user number will be selected by the system and the normal user programming menu will be displayed. User xxxx Present Card/Fob Present the card or fob for the new user The user authority is automatically set to Access for all doors and the user text descriptor will be defaulted.
PX Control Panel User Manual – Issue C Code-54 Door Lockout Enter the door number: Door Lock Menu Door-nn Door Lockout-Off Options On/Off The locked out door will remain locked and will refuse all access attempts until the lockout is removed. The door lockout can only be removed through this programming option. The door lockout will over-ride any user/door schedule permissions or otherwise immediately, and for the applied duration.
PX Control Panel User Manual – Issue C Cct Status Code-89 The circuits that are on soak, bypassed or isolated can be displayed. Cct Status Normal The display will scroll all circuits that are bypassed, isolated or shunted.
PX Control Panel User Manual – Issue C System Details Number of Areas Number of keypads Number of Circuits Number of Users Service Number Contract Number Keypads Number Location 1 2 3 4 5 6 7 8 Set Groups Number Description 1 1 2 3 4 5 6 7 - 46 - 2 3 Areas 4 5 6 7 8
PX Control Panel User Manual – Issue C Number Description 1 8 - 47 - 2 3 Areas 4 5 6 7 8
PX Control Panel User Manual – Issue C Circuits Number Description Location Cct 1 Cct 2 Cct 3 Cct 4 Cct 5 Cct 6 Cct 7 Cct 8 Cct 9 Cct 10 Cct 11 Cct 12 Cct 13 Cct 14 Cct 15 Cct 16 Cct 17 Cct 18 Cct 19 Cct 20 Cct 21 Cct 22 Cct 23 Cct 24 - 48 -
PX Control Panel User Manual – Issue C Number Description Location Cct 25 Cct 26 Cct 27 Cct 28 Cct 29 Cct 30 Cct 31 Cct 32 Cct 33 Cct 34 - 49 -
PX Control Panel User Manual – Issue C Users Number Name Authority Level 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 - 50 - 2 Areas or Set Groups 3 4 5 6 7 8
PX Control Panel User Manual – Issue C Number Name Authority Level 1 27 28 29 30 31 32 33 34 35 36 37 38 39 40 - 51 - 2 Areas or Set Groups 3 4 5 6 7 8
Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Tel: 0131-333-2900 FAX: 0131-333-4919 Technical Hotline: 0131-333-3802 Part Number: 320680-0C