User's Manual

TagExciterInstallationManual 0700051110
©
2010GuardRFIDProprietaryandConfidential
Indicators Off On Flashing
LED5 RedPowerFaultLED. Normal Over/undervoltage N/A
AlarmLED
RedLED,TEinundesirable
conditionwhenflashing
Normal N/A
TEError‐CheckError
codedisplay
FieldLED YellowLED LFFieldoff Normal‐LFfieldon Recalibratingfieldsize
CommLED GreenLED
Noinput
voltage
Networkcommunication
established
Poweron,nonetwork
communication(Normal
operationfor@Guard)
LFLED LitwheninLFadjustmode Normal InLFadjustmode N/A
IDLED LitwheninIDadjustmode Normal InIDadjustmode N/A
RFLED
UHFSensitivitySetting
(Notused)
Normal In
RFadjustmode N/A
MODLED
LitwhenadjustingMODE
features
Normal InModeselectmode N/A
7Seg.LED
Readout
Numericalindicator
showingstatusorlevel
Normal Indicatescurrentcondition N/A
TagExciterPowerConnections
TheTEinputvoltageis12VDCandmaybepoweredbyacentralpowersupplyoraPoESplitter
andaPoEnetworkswitch.NotethattheTEconnectstothenetworkusinga433MHzlinktothe
TRCanddoesnotrequireaTCP/IPconnection.PoEPoweredTEsdonot
usethedatacomponent
ofthePoEswitch.
WhenpoweringtheTEwithaPoESwitch,ensuretousetherecommendedPoESplitter
(GuardRFIDP/N6124002).PoEvoltageis48VDCfromtheswitchandneedstobe
convertedto12VDCtopreventdamagetotheTRC.
ConnecttheTE
to12VDC/1ApowersourceeitherfromthePoESplitterora12VDCcentralpower
supplyasshownbelow.PowersupplyvoltagefortheTEmustnotexceed14VDC.
EnsuringCompliancewithRFIRulesandRegulations
InordertoensurecompliancewithrelevantRFIrulesandregulations,thecableusedtosupply
powerforTagExcitermusthaveferritesuppressorattached.Theferritesuppressorissupplied
withTagExciterandshouldbeclampedontothepowercableascloseaspossibletoTagExciter
enclosure.
Thepart
numberofferritesuppressorisBF1835,manufacturedbyAPIDelevanInc.Any
equivalentferritesuppressorcanbeused.