User's Manual
Galaxy G6
- 88 -
Using internal Web UI
1) Connect Galaxy G6 with computer via 7-pin to USB cable and set the USB port to output
as Ethernet on G6. (a driver is required to installed on computer to enable this function).
2) Login the internal Web UI of G6 with the default username and password (admin/admin).
3) Get into “General Config” interface under “Configuration”;
4) Choose “Base” in “Work Mode” and “Radio” for “Datalink”, then click “Enter” button to
save configurations;
5) Get into “Base Setup” interface, and input known coordinates or click “Position” button to
obtain a single coordinates for base station;
6) Choose the correction format in “Corrections”, then click “StartBase” button to start the