User's Manual

User Manual
2
Step3 Mounting In-Wall Box
Mount wall switch and cover plate back to the in-wall box.
Step4 Restoring Power
Restore power at circuit breaker or fuse. Installation is complete.
Operation
INCLUDING device into Z-Wave network:
1. Set controller into INCLUSION mode. Follow the instructions provided by the
controller/gateway manufacturer.
1. Press the momentary button on the device, or the connected external button S1 3 times in
quick succession.
Note: If the inclusion is successful, the INDICATION LED will blink slowly 6 times, If not,
INDICATION LED will be solid on or off depending on switchs state.
EXCLUDING device from Z-Wave network:
2. Set controller into EXCLUSION mode. Follow the instructions provided by the
controller/gateway manufacturer.
3. Press the momentary button on the device, or the connected external button S1 3 times in
quick succession.
Note: If the exclusion is successful, the INDICATION LED will blink slowly 6 times. If not,
INDICATION LED will be solid on or off depending on switchs state.
Turning on/off the device:
The device can be controlled by:
Toggling/pressing external panel Switch/Button.
Sending commands through controller/gateway.
the command classes which support this function are Basic_Command_Class,
Binary_Switch_Command_Class, and Multi_Channel _Command_Class
Multi Channel control:
The device can be controlled by command “MULTI_CHANNEL_ENCAP” in the command class
COMMAND_ CLASS_MULTI_CHANNEL: ( This device supports one End Point.)
Byte
Content
1
Command Class = COMMAND_CLASS_MULTI_CHANNEL
2
Command = MULTI_CHANNEL_CMD_ENCAP
3
Source End Point
4
Destination End Point
5
Command Class = COMMAND_CLASS_SWITCH_BASIC or
COMMAND_CLASS_SWITCH_BINARY
6
Command = BASIC_SET or BASIC_GET
or BINARY_SET or BINARY_GET
7
Value( 0xFF -- ON 0x0 -- OFF )