User's Manual

11
FunctionCheck ID of call sign
ExampleID show “123
3.2.41 TIMEID parameter
FunctionSet the sending interval of call sign (unit: min)
Parameter0~255
ExampleTIMEID 2 show “PROGRAMMED OK”
3.2.42 TIMEID
FunctionCheck sending interval of call sign
ExampleTIMEID show “2
3.3 Special commands (special commands work only with antenna, so antenna must be connected before
testing)
3.3.1 CCA parameter
FunctionCheck the received signal strength value (dBm) of the specified channel (MHz).
Parameter choice410.000 470.000
ExampleCCA 466.125 show (two options)
1 CCA parameter 1parameter 2Example CCA 466.125:-106.125indicate the
received signal strength value is -106.125 dBm in the current 466.125MHz channel.
2 CCA 466.125:ERRORindicate the test is failed, but it is not indicated that all the
channels to be tested aren’t applicable. It indicates only the failure for the test operation without
connecting the antenna, or too close to the emission source, etc. may lead to the test failure.
3.3.2 RSSI
FunctionCheck the received signal strength value.
ExampleRSSI show (two options)
1 RSSI indicates it doesnt receive any data in the protocol, so it cant show the received signal
strength value.
2 RSSI -52.478 -48.063-52.478dBmRefers to the average value of the signal strength
received in the last 20 times or less than 20 times in the protocol (because from power-on
to the execution of the RSSI command, no more than 20 data packets are received in the
protocol); -48.063 (unit: dBm) refers to the received signal strength of the last intra-protocol
packet reception of RSSI command execution.
3
Main Power Supply
TRM101 can operate with any 3.3V power supply, which comes from data interface connector with good filtered.
The power must supply 1A current at least and featured with current-limiting, even if you make radio modem
operating on low power mode (0.5W).