User's Manual

10
FunctionCheck L-grade power indicator
Example PWRL show0.500
3.2.26 PWRH
FunctionCheck H-grade power indicator
ExamplePWRH show1.000
3.2.27 SPRT
FunctionCheck the supported protocols
ExampleSPRT show
TRIMTALK;TRIMMK3;SOUTH;TRANSEOT;GEOTALK;GEOMK3;SATEL; HITARGET; PCCEOT; PCCFST;
SATEL_ADL; PCCFST_ADL
3.2.28 SBAUDRATE
FunctionCheck air baud rate(unitbps)
ExampleSBAUDRATE show4800; 9600; 19200
3.2.29 TEMP
FunctionCheck current temperature()
ExampleTEMP show36.808
3.2.30 U
FunctionCheck present supply voltage.
ExampleU show3.288
3.2.31 RPTparameter
FunctionSet relay mode
ParameterON/OFF
ExampleEnable relay function “RPT ON, show “PROGRAMMED OK
3.2.32 RPT
FunctionCheck relay mode
ExampleRPT show “RPT OFF
3.2.33 FECparameter
FunctionSet FEC function switch
ParameterON/OFF
ExampleEnable FEC function “FEC ON” show “PROGRAMMED OK
3.2.34 FEC
FunctionCheck FEC function state
ExampleFEC show “FEC ON
3.2.35 RIP parameter
FunctionSet protocol correction on output (only for TRANSEOTTRIMTALKTRIMMK3)
ParameterON/OFF
ExampleEnable RIP function “RIP ON” show “PROGRAMMED OK”
3.2.36 RIP
FunctionCheck RIP function state
ExampleRIP show “RIP ON
3.2.37 CSMA parameter
FunctionSet carrier to sense multiple access
ParameterON/OFF
ExampleEnable CSMA function “CSMA ONshow “PROGRAMMED OK
3.2.38 CSMA
FunctionCheck CSMA function state
ExampleCSMA show “CSMA ON”
3.2.39 ID parameter
FunctionSet ID number for call sign
Parameter16-digit ID number (if less than 16 digits, 0 to16 digits will be added automatically
in front of ID)
ExampleID 123 show “PROGRAMMED OK”
3.2.40 ID