Figure 30 Configuration interface for Read/Write command parameters
Failed retry N times
For example, the read data block command is likely to fail in a disturbed
environment, the anti-jamming capability can be enhanced by trying multiple times.
Unidentified tag type: The following configuration requires professional
knowledge
Block size: the number of bytes per block, NXP ICODE SLI series chips are 4
bytes per block;
Read block command: for unrecognized tags, we do not know whether it
supports reading single block and reading multiple blocks, if both are
supported, then choose to " Read multiple blocks";
Write block
Commandfor unrecognized tags, we don't know whether it supports writing
single block and writing multiple blocks, if both are supported, then choose to
"Write multiple blocks";
6.1.7. Antenna Port Parameters
Figure 31 Configuration interface for antenna port parameters
Enable DC: when checked, the reader antenna interface is output with electricity.