User's Manual

User manual
Guangzhou Andea Electronics Technology Co., Ltd. 6/26
http://www.gzandea.com
Figure 6 DB9 connector
Parameters Description of RS232 communication interface:
Baud rate: 38400
Data bit: 8
Parity: even parity
Stop bit: 1
Default address: 1
Definition of interface pin (as shown in the below sheet):
Table 4 RS232 interface pin definition description
Pin
Signal
Description
1
NC
Reserved
2
TXD
RS232 data output
3
RXD
RS232 data input
4
NC
Reserved
5
GND
Ground
6
NC
Reserved
7
NC
Reserved
8
NC
Reserved
9
NC
Reserved
Remarks: If the user's computer does not have RS232 serial port, you can choose
our USB to RS232 converter (non-standard products, must be purchased separately),
after installing the USB driver, you can use the reader through the connected computer
USB interface.