User's Manual

User manual
Guangzhou Andea Electronics Technology Co., Ltd. 13/26
http://www.gzandea.com
Max timeout: the maximum time to read a card on an antenna;
Special application:
Disable Anti-collision:
Disable anti-collision doesn't mean reading only one tag. If it is an inventory
of 1 slot, it can read up to 2 tags after turning off this function. If it is an
inventory of 16 slots, turning off this function can read up to 16 tags.
Disable stay quiet:
If the feature is checked, it will not sleep after the tag inventory.
Enable probe command: the speed can be increased in the case of multiple
antennas.
t3(us) : the default value of this time is 0. Changing this time will affect the
time of inventory.
Next round delay(ms): next round delay(ms) time of regenerate the response.
Anti-collision type:
A. ISO15693 standard
B. ICODE SLI Persistent
6.1.6. Read/Write Command Parameters
Figure 17 Configuration interface for Read/Write command parameters
Failed retry N times:
For example, the read data block command is likely to fail in a disturbed
environment, the anti-jamming capability can be enhanced by trying multiple times.
Unidentified tag type: The following configuration requires professional
knowledge