6.1.5. Inventory General Parameters
Figure 16 Configuration interface for inventory general parameters
⚫ Basic:
① Beep when tag found: if this option is checked, the buzzer will sound when a
tag is detected.
② AFI Enable: if this option is checked, the AFI value of the comparison tag
required during the inventory process can be filled in the following AFI parameters;
③ AFI Value: this parameter is valid only if the" AFI Enable" option is checked;
④ Slot type:
1 Slot: suitable for inventory within 8 tags;
16 Slot: when the number of tags is more than 8, it is more appropriate to use
16 slots than 1 slot;
⑤ Stop trigger: the trigger condition for the inventory stop.
Exit condition: when the inventory command is executed on an antenna, set
the conditions for inventory stop;
A. Attempt N times;
B. Max timeout;
Value of attempt N: this parameter is only valid when "Exit condition" is
selected as A;