User's Manual
User Manual
Andea Electronics http://www.gzandea.com Page 35 Total 44 Pages
Set the [Detection method - Way to check if book in Library] to "EAS and
AFI", set the EAS and AFI detection parameters, and [Trigger alarm conditions] set
to "Alarm when books are detected":
This setting item realizes double detection of EAS and AFI functions. For the
test method, please refer to the description of points 1 and 2 above.
Figure 34 Alarm Condition Setting Using EAS and AFI
6.2 Card Reading Range Test
Set the alarm condition detection content to "EAS", and place the book with
the tag in a direction perpendicular to the middle of the gate. When it is detected
normally, the vertical distance between the book and the external connection line of
the S and M gate antenna is about 60CM while the distance of the book parallel to
the gate is about 100CM, as shown below: