User's Manual

User Manual
Andea Electronics http://www.gzandea.com Page 24 Total 44 Pages
Figure 18 Interface for System Error Flag
Table 9 Description for System Error Flag
5.5 Data Collection
Data collection, can obtain the historical records of the daily flow of in and
out traffic (records before the current day) and the UID number, date and
designated tag data block content recorded after the alarm is triggered. Click the
"Start" button to extract the data. "Clear list" only means to clear the table data on
No.
Error Flag
Description
0
Client offline
error
The gate is disconnected. Check whether the gate
connection line is loose or disconnected.
1
Manual
suspend to
read card
The anti-theft detection function is suspended. Click
"Resume Anti-theft" in the control command.
2
Data store
error
Alarm records and people flow cannot be saved in the
control center and the generated records will be lost.
3
System clock
error
The control center system clock stops, which will result
in incorrect time stamps for the resulting records.
4
MAC
address error
Failed to read the MAC address of the Ethernet. If both
devices have this fault, the MAC addresses of the two
devices in the same LAN will conflict and cannot
communicate.