User's Manual
User Manual
Andea Electronics http://www.gzandea.com Page 18 Total 44 Pages
Length
The length of the barcode data, the default value is
16
Unrecogniz
able Tag
Data block length: the number of bytes in each
block, NXP ICODE SLI series chips are 4 bytes per
block.
Read command: For unrecognized tags, we do not
know whether it supports read single block and read
multiple block instructions. If both are supported,
then select read multiple blocks.
Acousto-
optic
Alarm
Trigger condition
Can be set to trigger an alarm under the following
conditions:
1. None - No sound and light alarm is triggered, and
the alarm is triggered by an external command.
2. Alarm when books are detected - Alarm when a
book is detected (default setting)
3. Alarm when reading UID and barcode - Read the
UID and barcode data before alarming
Enable broadcast
alarm
Tick for broadcast, all gates alarm when a book is
detected.
Untick, only the specific detecting gate alarms.
Default broadcast.
Alarm output
parameters
Flashing frequency: 3 times by default
Activation time: unit ms, default 100
Invalid time: unit ms, default 100
Closer buzzer
Tick to turn off the buzzer. Default: untick
Data
Store
Alarm record stored
position
By default FLASH, the alarm record is saved in
flash and it will not disappear at any time. It can be
read at any time. Optional RAM, the alarm record is
saved in RAM. It will disappear after power failure,
and the old record will be overwritten after
overflow. So, it needs to read in real time.
How many seconds
does the same tag
saved only one
record
The same UID alarm filtering interval. The default
is 3S. If the alarm is the same tag within 3S, only
one alarm record is generated.