Version:1.0 User Manual Blood Pressure Monitor LS802-E Arm Type FCC ID:OU9LS802-E02 GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO.,LTD Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch Development District, Zhongshan, Guangdong, 528437, China Thank you very much for selecting TRANSTEK Blood Pressure Monitor LS802-E. To use the monitor correctly and safely, please read the manual thoroughly. please keep well this manual in order to reference in future.
CATALOGUE CATALOGUE Table of Contents INTRODUCTION ..............................................................................................................................2 General Description Safety Information LCD Display Signal Monitor Components BEFORE YOU START......................................................................................................................6 The Choice of Power Supply Installing and Replacing the Batteries MEASUREMENT.......................................
INTRODUCTION INTRODUCTION CAUTION General Description Thank you for selecting TRANSTEK arm type blood pressure Monitor (LS802-E). The monitor features blood pressure measurement, pulse rate measurement and the the result storage. The design provides you with two years of reliable service. Reading taken by the LS802-E are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method.
INTRODUCTION INTRODUCTION LCD Display Signal Monitor Components CUFF AIR PIPE AIR CONNECTOR PLUG LCD DISPLAY SYMBOL DESCRIPTION EXPLANATION Systolic blood pressure High pressure result DC POWER SOCKET Diastolic blood pressure Low pressure result 4 Pulse Pulse/minute User 1 Provide measurement for user 1, and then save the measure data User 2 Guest User 1 Guest Provide measurement for guests, but not save the measurement data.
BEFORE YOU START MEASUREMENT The Choice of Power Supply Tie the Cuff 1.Battery powered mode: 6VDC 4*AA alkaline batteries 1.Tie the cuff on your upper arm, the position the tube off-center toward the inner side of arm in line with the little finger. 2.AC adaptor powered mode: 100-240V~, 50-60HZ,400mA (Can be supplied by AC adaptor model UE08WCP-060100SPA only!) Please unplug the adaptor to depart from the using utility power.
MEASUREMENT MEASUREMENT Start the Measurement Press the User 1 button to turn on the monitor and it will finish the whole measurement, and then save the measure data for User 1. The same to the User 2. Press the Guest button to turn on the monitor and it will finish the whole measurement for Guest, but not save the measurement data. In this manual, the measurement of User 1 as an example. 1.
INFORMATION FOR USER INFORMATION FOR USER Tips for measurement It can cause incorrectness if the measurement are taken in the following circumstances. 10 Within 1 hour after dinner or drinking Immediate measurement after tea, coffee, smoking Within 20 minutes after taking a bath When talking or moving your fingers In a very cold environment When you want to discharge urine Maintenance In order to get the best performance, please follow the below instructions.
ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure? When ventricles contract and pump blood out of the heart, blood pressure reaches its maximum value, the highest pressure in the cycle is known as systolic pressure. When the heart relaxes between heartbeats, the lowest blood pressure is diastolic pressure.
TROUBLESHOOTING SPECIFICATIONS This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor. If the products not operating as you think it should, check here before arranging for servicing. Battery powered mode: 6VDC 4*AA alkaline batteries AC adaptor powered mode: Power supply 100-240V~, 50-60HZ,400mA (Can be supplied by AC adaptor model PROBLEM SYMPTOM No power Low batteries Display will not light up.
FCC STATEMENT AUTHORIZED COMPONENTS Authorized Components 1.Please use the TRANSTEK FCC Statement 2.Storage bag. authorized adaptor. Adaptor Type:UE08WCP-060100SPA Input:100~240V,50~60Hz,400mA Output:6V 1A (Conforms to UL certificate) Contact Information For more information about our products, please visit www.transtek.cn.you can get customer service, usual problems and customer download, transtek will serve you anytime. Manufactured by: GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO.
EMC GUIDANCE COMPLIED STANDARDS LIST Complied Standards list Risk management ISO/EN 14971:2012 Medical devices — Application of risk management to medical devices Labeling ISO/EN 15223-1:2012 Medical devices. Symbols to be used with medical device labels, labelling and information to be supplied.