User Manual
UHF Integrated RFID Reader Manual
Guangdong Sygole Intelligent Technology Co.,Ltd
22
Fig 5.3 Antenna down-radiation field distribution map
6. Networking Application
Sygole I84/I85/I86 series products support multiple communication modes. During
networking application, the user may select a suitable communication mode according
to the practical application conditions. Generally speaking, the hardware topology
graph for application is as shown in the following figure:
6.1 Field bus communication mode
In some cases, the field bus communication mode should be adopted to meet such
application requirements for large amount of RFID reader heads and high data
timeliness.Sygole I84/I85/I86 series products can support the field bus through gateway
controller, and support such protocols as ProfiNet, EtherCAT, Ethernet/IP, DeviceNet,
CCLINK and MODBUS TCP. Specifically, readers are connected to the gateways
which are mutually connected in series. In this way, all readers can be connected to the
same network. Specifically, the networking mode is as follows: