Operation Manual
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd
3.3.4 Power supply and wiring requirments
3.3.4.1 Wiring requirements
In industrial environment, correct ground connection is the main method for noise
suppression and interference prevention, and the main interference of the equipment circuit is
sourced from the unreasonable ground wire. Therefore, it is import to correctly handle the ground
connection of the circuit in order to ensure the normal operation and the read/write success rate of
the reader.
Under normal circumstances, the power voltage of the reader equipment is 24V, belonging to the
low voltage, so the power wire and 485 power wire of the reader should be connected to the weak
current trunking during wiring, and the trunking must have standard ground connection (“0”
electric potential). If the trunking and the shielding layer cannot be connected to the standard
“0” electric potential, the power supply should follow relevant regulation in 3.3.4.2.
3.3.4.2 Power supply requirements
In industrial environment, electromagnetic interference has such characteristics as complexity,
variability and uncontrollability and usually enters the reader through power supply coupling to
generate adverse impact and cause abnormal operation of the reader, so power interference is one
of the most harmful main interference sources. In order to eliminate such conduction interference,
it is suggested to provide independent power supply or set a filter at the power terminal for RFID.
4. Reader
4.1 Product features
SG-HR-I series reader products have the features as shown in Tab. 4.1:
Tab. 4.1 SG-HR-I Series Reader Product Features
Reader
Product
Features
SG-HR-I1
Working
frequency
13.56MHZ
Supported
protocol
ISO15693
communicatio
n interface
RS485
RS232
Read-write
distance
0~30 mm
Shell material
Nickel plated
brass + ABS
The products with different communication interfaces have different order models. Specifically,
the order model of each product is as shown in the following table:
Communication
interface
Model
RS232
RS485
SG-HR-I1
SG-HR-I1-RS232
SG-HR-I1-RS485