Operation Manual

High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd
Fig. 3.6 Static Mode Operation Diagram
Note: in metallic environment, both the reader and the tag may cause certain loss influence on the
recognition distance, so it is necessary to prevent the metal from directly surrounding the reader or adopt
anti-metal tag to increase the recognition distance.
3.1.4.2 Dynamic mode
During the operation under dynamic mode, the tag can dynamically pass through the
transmission window, and the movement speed of the tag relatively to the reader must meet the
following formula:
𝑉
2𝐸
3T
V: relative movement speed of tag and reader head;
E: read eccentric distance of tag and reader head at application distance;
T: command execution period;
SG-HT-263 tag (surface length is 6 CM, and width is 3.3 CM) and SG-HR-15 tag are taken as
examples. When the application distance is 6 CM, the eccentric distance is 6 CM. When the
automatic tag memory read mode is adopted (16 bytes are read, and the command execution
period is 30ms), the applicable speed is as follows:
𝑉
2 6𝑐𝑚
3 30ms
= 1.34𝑚/𝑠
Note: in practical project application, if there is any metal around the tag and the reader head, the eccentric
distance will be reduced; the actually measured value should prevail in such case.
3.2 Reader and tag data
3.2.1 Read distance of the reader
The critical distance (Sg), the operation distance and the transmission window length
corresponding to different readers are as shown in the following table: