Users Manual

23
X3HH/X3PP
In the power-on state, press the CH button of the handheld microphone
for 2 seconds to enter the frequency modulation mode. When the channel
on the display screen is flashing, click the CH button to switch the
frequency code, and each click switches a frequency code. Press the CH
button again for 2 seconds to confirm the frequency code and enter the
automatic frequency matching mode with digital scrolling display "----".
Align the IR matching window of the handheld microphone with the IR
matching window of the receiver in a straight line (the matching distance is
recommended to be between 10cm-50cm). Click the power switch of the
receiver to enter the frequency matching mode, and the corresponding
channel signal of the receiver flashes red and green. After the matching is
successful, the receiver lights up green.
Note: After the handheld microphone enters the frequency matching
mode, please complete the operation within 5 seconds. If the matching
fails, please repeat the above steps.
Handheld microphone
Bodypack transmitter
In the power-on state, press the SET button of the bodypack transmitter
for 2 seconds to enter the frequency modulation mode. When the channel
on the display screen is flashing, click the "+" or "-" button to switch the
frequency code, and each click switches a frequency code. Press the SET
button again for 2 seconds to confirm the frequency code and enter the
automatic frequency matching mode with digital scrolling display "----".
Align the IR matching window of the bodypack transmitter with the IR
matching window of the receiver in a straight line (the matching distance is
recommended to be between 10cm-50cm). Click the power switch of the
receiver to enter the frequency matching mode, and the corresponding
channel signal of the receiver flashes red and green. After the matching is
successful, the receiver lights up green.
Note: After the bodypack transmitter enters the frequency matching mode,
please complete the operation within 5 seconds. If the matching fails,
please repeat the above steps.