Step 3
With the gate in the desired open position PRESS & HOLD the “SET LIMIT"
button on the control board for 5 seconds.
Step 4
Press the transmitter button and allow the gate to return to the closed position.
YOUR GATE’S OPEN POSITION LIMIT IS NOW PROGRAMMED.
TESTING YOUR OPEN LIMIT SETTING:
Press your entry transmitter and allow your gate to open. If the OPEN position
is not correct or need to be changed, you will need to CLEAR your OPEN
LIMIT settings and follow steps one (1) to four (4) again.
CLEARING PROGRAMMED OPEN LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your
transmitter to return the gate to the closed position, then press and hold the
"SET LIMIT" button for 10 seconds. This will clear the memory for the open
limit position. Follow steps one (1) to four (4) again.
1
ON
2 3 4 5 6 7
SET
LIMIT
LEARN
TRANSMIT
TER
MODES
ON
OFF
1 2 3 4 5 6 7
Set Limit Button
STALL FORCE
M
I
N
M
A
X
GRN
BLK
RED
RECEIVER
COM COM
CYCLE
CLOSE
SAFETY
EXI
T
OPEN
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
J11
J8
J12