User Guide
25
1
ON
2 3 4 5 6 7
ON
OFF
1 2 3 4 5 6 7
DIP#6 DIP#7 Delay Time for Auto-Close
ON ON 15 seconds
ON OFF 30 seconds
OFF ON 60 seconds
OFF* OFF* 120 seconds (factory preset)
DIP#5
ON
D1 mode, constant pressure to operate gate.
OFF*
B2 mode, momentary contact to operate gate.
DIP#4
ON Push-to-open operation.
OFF* Pull-to-open operation.
DIP#3
ON Auto-close enabled.
OFF* Auto-close disabled.
DIP#2
ON* Buzzer warning enabled.
OFF Buzzer warning disabled
DIP#1
ON* Soft start enabled.
OFF Soft start disabled.
* Factory Preset.
CONTROL BOARD SETTINGS
DIP Switches
Main DIP Switch Settings (MODES)
DIP Switch #1 - Soft Start/Stop
The Soft Start/Stop feature slowly starts the
gate as it begins to open and slows the gate
as it comes to the closed position. This saves
wear and tear on the gate and gate operator
system.
DIP Switch #2 - Warning Buzzer
The Warning Buzzer alerts you when the gate
operator is beginning to either open or close
the gate. It sounds for the first 2 seconds in
each direction. It also sounds a warning when
the gate obstructs two times in one cycle.
Switching this to OFF only disables the
open and close warning not the obstruction
warning.
DIP Switch #3 - Auto-Close
With the Auto-Close switch in the OFF
position the gate will remain open until it
receives another signal from an activation
device such as a transmitter, keypad, or push
button control. With the Auto-Close switch
in the ON position the gate operator will
automatically close the gate, if the gate is
in it's open limit position. The time the gate
will remain open is determined using DIP
Switches #6 and #7.
DIP Switch #4 - Push/Pull-to-Open
If your gate opens into the property the DIP
Switch is set to OFF (factory). If your gate
opens out from the property the DIP Switch
must be set to the ON position.
DIP Switch #5 - B2/D1 Mode
This DIP Switch must remain in the OFF
position unless the gate operator is going to
be used by a guard or gate attendant, who can
only open the gate when constant pressure is
applied to a push button control device.
DIP Switches #6 and #7
The combination of these two switches
determines the amount of time the gate will
remain open when DIP Switch #3 is set in the
ON position.
IMPORTANT CONTROL BOARD SETTINGS:
CONTROL BOARD DIP SWITCH #1 is factory
preset in the ON position and MUST remain in the
ON position. Changing this setting can damage
your gate, gate opener and
possibly void your warranty!