Step 2
Make sure the control box power switch is in the OFF position. The ON/OFF
Switch is located on the bottom of the control box. Remove the control box
cover and slide the battery into position with its terminals to the RIGHT (see
illustration). Connect the BLACK battery wire to the NEGATIVE () battery
terminal. Connect the RED battery wire to the POSITIVE (+) terminal. Pay
close attention to the color of the wires. If the wires are connected incorrectly,
the control board will be damaged. NEVER insert the battery with the
terminals to the left.
Mounting the Control Box
Step 3
Strip approximately
3
/16" of insulation from each wire of the power cable. Twist
each exposed wire tightly (there are seven [7] wires inside the power cable sheath).
Loosen sealing nut on strain relief hub at bottom of control box. Insert power cable
into control box through strain relief. Thread approximately 6" of the power cable
into the control box and retighten sealing nut until the power cable locks into place.
Step 1
Mount the control box using the screws (provided) or another
secure mounting method. The control box must be mounted at
least 3 feet above the ground to protect it from rain splash,
snow, etc., and at least 3 feet from an AC power source to
prevent electrical interference.
RED wire to POSITIVE (+) terminal
BLACK wire to NEGATIVE () terminal
RED
BLACK
Sealing Nut
Hub
Lock Nut
Strain Relief
NOTE: The battery that came
with your GTO/PRO® 4000/4200,
MUST be placed in the top
(horizontal) battery slot with the
terminals on the RIGHT. The
extra (vertical) battery slot is for
an optional second battery. An
optional second battery can be
used for solar and/or high traffic
applications, if needed..
Use mounting
holes and screws
provided to mount
control box to a
secure surface.
1
ON
2 3 4 5 6 7
1
ON
2 3 4
15
18VAC RECEIVER
BAT
+
SWITCH
FUSE
ALARM
SWITCH
DUAL
MODES
SET
LIMI
T
LEARN
TRANSMITTE
R
MODES
ON
OF
F
ON
OF
F
1 2 3 4 5 6 7
1 2 3 4
BAT
SOLAR RELAY OUT SLAVE INPUTS
GRN WHT BLUE BRN ORG RED BLKNC RLY-COM NO
MASTER INPUTS
GRN WHT BLUE BRN ORG RED BLK COM COM
CYCLE
CLOS
E
SAFETY
EXIT
/
OPE
N
SHADOW
LOOP
CLOS
E
EDGE
OPE
N
EDGE
BLKGRN RED
+~~
12'
10'
8'
14'
16'
GATE LENGT
H
800-543-GATE
www.gtoinc.com
GTO, Inc.
3121 Hartsfield Rd
Tallahassee, FL 32303
Operator Power Cable
12 V Battery (Included)
Strain Relief
1
ON
2 3 4 5 6 7
1
ON
2 3 4
15
18VAC RECEIVER
BAT
+
SWITCH
FUSE
ALARM
SWITCH
DUAL
MODES
SET
LIMI
T
LEARN
TRANSMITTE
R
MODE
S
ON
OF
F
ON
OF
F
1 2 3 4 5 6 7
1 2 3 4
BAT
SOLAR RELAY OUT SLAVE INPUTS
GRN WHT BLUE BRN ORG RED BLKNC RLY-COM NO
MASTER INPUTS
GRN WHT BLUE BRN ORG RED BLK COM COM
CYCLE
CLOS
E
SAFET
Y
EXIT
/
OPEN
SHADOW
LOOP
CLOS
E
EDGE
OPEN
EDGE
BLKGRN RED
+~~
12'
10'
8'
14'
16'
GATE LENGT
H
800-543-GATE
www.gtoinc.com
GTO, Inc.
3121 Hartsfield Rd
Tallahassee, FL 32303
Single Battery
Installed Horizontally
with terminals on the right.
Dual Batteries
Installed Vertically
with terminals on bottom
.