IF THIS OPERATOR WILL BE USED WITH GATES THAT ARE MOUNTED ON
MASONRY, BRICK, OR ROCK (etc.) COLUMNS:
READ THE FOLLOWING CAREFULLY BEFORE PROCEEDING
A. The simplest solution is to install the operator in a push-to-open configuration. The minimum clearance is
easier to achieve and clearance is no longer a problem, since the operator will be pushing the gate away from
the column instead of pulling it toward the column. It is recommended that you place a steel plate between the
operator mounting brackets and masonry surface for additional strength.
B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the
gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the
back corner of the columns.
C. The most difficult solution is to cut a notch in the column to accommodate the operator and power cable. This
job is NOT for the inexperienced!
Column
Pivot Bracket
Gate
A
B
Column Mount Example
(A + B can not exceed 17 inches)
Example: If A is 2" then B can not exceed 15"